Keep the air hose as short and free of cur- ves as possible to avoid bottlenecks.

Air-conditioning with installation

If required, your appliance can be installed semi- permanently (Fig. 6).

Proceed as follows:

Drill a 5.27 inch (134 mm) dia. hole in an outside wall or through a window pane, re- specting the heights shown in fig. 7.

6

12 inch

30 cm

12 inch

30 cm

Fit the flange accessory (S) provided in the hole following the indications in figs. 8, 9 and

10.

7

MAX 39 inch

MIN 14 inch

8

5 inch 134

in the window pane

9

in the wooden kickboard of a French window

10

in the wall: you are recommended to insulate the section of wall using suitable insulation.

Fit the air exhaust hose (K) in the housing at the back of the appliance (fig. 1).

Fit the end of the hose to the flange (S). When the hose is not fitted, the hole can be closed with the flange cap.

Remove the cap at the back of the appliance

(G)and replace with the drain hose plus cap

(U)as shown in figure 11. This enables the condensate to be drained more easily at the end of the season. See the section: “END OF SEASON OPERATIONS”.

Keep the air hose as short and free of cur- ves as possible to avoid bottlenecks.

When installing the air conditioner semi- permanently, you should leave a door slightly open, as little as 0.5 inch (1 cm), to guarantee correct ventilation.

11

6

Page 6
Image 6
DeLonghi WE 110, WE 130, WE 115 manual Air-conditioning with installation, Window pane Wooden kickboard of a French window