MOUNTING THE AIR CLEANER TO THE CEILING OR

MOUNTING THE AIR CLEANER TO THE CEILING OR

OVERHEAD SUPPORT

OVERHEAD SUPPORT WARNING: THIS TOOL WEIGHS APPROXIMATELY 50 POUNDS. MAKE CERTAIN THE UNIT IS SECURELY SUPPORTED WHEN MOUNTING TO A CEILING OR OVERHEAD SUPPORT.

1.Remove four screws, one of which is shown at (C) Fig. 5, from the top of air cleaner (D).

2.Thread 5/16-18 flange nut (E) Fig. 5, approximately half-way onto 5/16-18x1½" eye-bolt (F), as shown.

3.Thread eye-bolt (F) Fig. 5, into hole where screw (C) was removed in STEP 1. NOTE: THREAD EYE-BOLTS

IN EIGHT COMPLETE TURNS.

4.Repeat this process for the three remaining holes in the top of air cleaner

5.Fig. 6, illustrates the four eye-bolts (F) attached to top of air cleaner. NOTE: To adjust the height of the air cleaner, loosen flange nuts (E) Fig. 5, and rotate eye- bolts as necessary. Eye-bolts must be threaded at least eight complete turns into tapped hole in air cleaner. Make certain the flange nuts (E) Fig. 5, are tightened down against the surface of the air cleaner after height adjustments are made.

When suspending the air cleaner from the ceiling or other overhead support, make certain the supporting hardware (not supplied) is securely anchored into a wooden supporting structure as shown in Fig. 7.

IN EIGHT COMPLETE TURNS. WARNING: NEVER SECURE MOUNTING HARDWARE TO DRYWALL, DROP CEILING TILE/FRAME, OR NON- STRUCTURAL MEMBERS.

Manual background WARNING: Keep a minimum of seven feet between bottom of air cleaner and the floor surface.

DO NOT use rope, cable or power cord to suspend the unit from the ceiling. We recommend that a chain should be used and rated for a minimum of a 150 lb. working load to firmly support the air cleaner. IMPORTANT: When determining a location to mount the unit, the air cleaner will operate more efficiently when the air flow is unrestricted. Do not locate the unit in a corner or near any heating or cooling vents.

F

Manual backgroundC

E

D

Fig. 5

F

Fig. 6

Fig. 7