Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50 4-73
ON OFF
01-09
07-05
Output freque ncy
Run /Stop Time
DC Brake Time
DC Brake Time
during St opping
Start
frequen cy
Start-point for
DC brake
time during
stopping
07-03 07-04
07-06 DC Brake Proportional Gain
Control
mode VF VFPG
Factory Setting: 50
Settings 1 to 500Hz
It is used to set the output voltage gain when brushless DC brake.
07-07 Reserved
07-08 Reserved
07-09 Reserved
07-10 Reserved
07-11 Fan Control
Control
mode VF VFPG FOCPM
Factory Setting: 1
Settings 0 Fan always ON
1 1 minute after DC brushless motor drive stops, fan will be OFF
2 Brushless DC motor drive runs and fan ON, brushless DC motor
drive stops and fan OFF
3 Fan ON to run when preliminary heat sink temperature attained
4 Fan always OFF
This parameter is used for the fan control.
When setting to 3, fan will start to run until temperature is less than 40°C if temperature
exceeds 40°C.
07-12 Reserved
07-13 Reserved