Revision May 2009, 00DE, V0.50 A-1

Appendix A Specifications

There are 115V, 230V and 460V models in the BLD-E1 series. For 115V models, it is 1-phase

models. For 0.25 to 3HP of the 230V models, there are 1-phase/3-phase models. Refer to following

specifications for details.

Voltage Class 115V Class
Model Number BLD-XXXE1 002 004 007
Max. Applicable Motor Output (kW) 0.2 0.4 0.75
Max. Applicable Motor Output (hp) 0.25 0.5 1.0
Rated Output Capacity (kVA) 0.6 1.0 1.6
Rated Output Current (A) 1.6 2.5 4.2
Maximum Output Voltage (V) 3-Phase Proportional to Twice the Input Voltage
Output Speed (RPM) 1~4000 RPM
Output Rating
Carrier Frequency (kHz) 2-15
Rated Input Current (A) 6.4 9 18
Rated Voltage/Frequency Single phase, 100-120V, 50/60Hz
Voltage Tolerance
±
10%(90~132 V)
Input Rating
Frequency Tolerance
±
5%(47~63 Hz)
Cooling Method Natural Cooling Fan Cooling
Weight (kg) 1.1 1.1 1.4

Voltage Class 230V Class
Model Number BLD-XXXE1 002 004 007 015 022 037
Max. Applicable Motor Output (kW) 0.2 0.4 0.75 1.5 2.2 3.7
Max. Applicable Motor Output (hp) 0.25 0.5 1.0 2.0 3.0 5.0
Rated Output Capacity (kVA) 0.6 1.0 1.6 2.9 4.2 6.5
Rated Output Current (A) 1.6 2.5 4.2 7.5 11.0 17
Maximum Output Voltage (V) 3-Phase Proportional to Input Voltage
Output Speed (RPM) 1~4000RPM
Output Rating
Carrier Frequency (kHz) 2-15
Rated Input Current (A) 4.9 6.5 9.3 15.7 24 --
XXXE
121A Rated
Voltage/Frequency Single 200-240 V, 50/60Hz
Rated Input Current (A) 1.9 2.7 4.9 9 15 20.6
XXXE
123A Rated
Voltage/Frequency 3-phase 200-240V, 50/60Hz
Rated Voltage/Frequency 1-phase/3-phase 200-240V, 50/60Hz
3-phase
200-240V,
50/60Hz
Voltage Tolerance
±
10%(180~264 V)
Input Rating
Frequency Tolerance
±
5%(47~63 Hz)
Cooling Method Natural Cooling Fan Cooling
Weight (kg) 1.2 1.2 1.2 1.7 1.7 1.7