Delta Electronics GBIC-1250B5QR specifications GBIC module definition parameters

Models: GBIC-1250B5QR

1 11
Download 11 pages 61.5 Kb
Page 6
Image 6
GBIC module definition parameters

GBIC-1250B5QR

GBIC module definition parameters

Module

MOD_DEF(0)

MOD_DEF(1)

MOD_DEF(2)

Interpretation by host Reference

Definition

Pin 4

Pin 5

Pin 6

 

0

NC

NC

NC

GBIC not present clause

 

 

 

 

Copper Style 1 or Style 2 connector, 1.0625 Gbd,

1

NC

NC

TTL LOW

100-TW-EL-S or 100-TP-EL-S, active

inter-enclosure connection and IEEE802.3

 

 

 

 

 

 

 

 

1000BASE-CX

 

 

 

 

Copper Style 1 or Style 2 connector, 1.0625 Gbd,

2

NC

TTL LOW

NC

100-TW-EL-S, or 100-TP-EL-S, active or passive

 

 

 

 

intra-enclosure connection

3

NC

TTL LOW

TTL LOW

Optical LW, 1.0625 Gbd 100-SM-LC-L

4

TTL LOW

SCL

SDA

Serial module definition protocol

5

TTL LOW

NC

TTL LOW

Optical SW, 1.0625 Gbd 100-M5-SN-I or

100-M6-SN-I

 

 

 

 

 

 

 

 

Optical LW, 1.0625 Gbd 100-SM-LC-L and similar

6

TTL LOW

TTL LOW

NC

to 1.25 Gbd IEEE802.3z 1000BASE-LX, single

 

 

 

 

mode

 

 

 

 

Optical SW, 1.0625 Gbd 100-M5-SN-I or

7

TTL LOW

TTL LOW

TTL LOW

100-M6-SN-I and 1.25 Gbd, IEEE 802.3z,

 

 

 

 

1000BASE-SX

GBIC timing parameters for GBIC management

Parameter

Symbol

Min.

Max.

Unit

Unit Conditions

TX_DISABLE assert time

t_off

 

10

μsec

Rising edge of TX_DISABLE to fall of output signal

 

 

 

 

 

below 10% of nominal

TX_DISABLE negate

t_on

 

1

mec

Falling edge of TX_DISABLE to rise of output

time

 

signal above 90% of nominal

Time to initialize,

 

 

 

 

From power on or hot plug fter V DD T > 4.75 volts

includes reset of

t_init

 

300

msec

or From negation of TX_DISABLE during reset of

TX_FAULT

 

 

 

 

TX_FAULT.

TX_FAULT from fault to

t_fault

 

100

μsec

From occurrence of fault (out-put safety violation or

assertion

 

 

 

 

V DD T < 4.5 volts)

TX_DISABLE time to

t_rest

10

 

μsec

TX_DISABLE HIGH before TX_DISABLE set LOW

start reset

 

 

 

 

 

 

RX_LOS assert delay

t_loss_on

 

100

μsec

From detection of loss of signal to assertion of

 

 

 

 

 

RX_LOS

RX_LOS negate delay

t_loss_off

 

100

μsec

From detection of presence of signal to negation of

 

 

 

 

 

RX_LOS

 

 

 

 

6

2008/01

 

 

 

 

 

Rev. 0A

DELTA ELECTRONICS, INC.

 

 

 

www.deltaww.com

Page 6
Image 6
Delta Electronics GBIC-1250B5QR GBIC module definition parameters, GBIC timing parameters for GBIC management