Delta Electronics GBIC-1250B5QR Absolute Maximum Ratings, Recommended Operating Conditions, Unit

Models: GBIC-1250B5QR

1 11
Download 11 pages 61.5 Kb
Page 2
Image 2
Absolute Maximum Ratings

GBIC-1250B5QR

Absolute Maximum Ratings

Parameter

Symbol

Min.

Storage Temperature

Ts

-40

Supply Voltage

VCC

0

Typ.

Max.

Unit

Notes

85ºC

6 V

Recommended Operating Conditions

Parameter

Symbol

Min.

Typ.

Max.

Unit

Notes

Ambient Operating Temperature

TA

-5

 

70

 

Supply voltage

Vcc

3.15 / 4.75

3.3 / 5

3.45 / 5.25

V

 

Total Supply Current

IS

 

 

300

mA

 

Data Output Load

RDL

 

75

 

Ω

 

Relative Humidity (non condensation)

-

5

 

85

%

 

Transmitter Electro-Optical Performance Specifications:

(TA=-5 °C to 70 °C, VCC=3.15V to 3.45V or VCC=4.75V to 5.25V)

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Transmitter

 

 

 

 

 

 

Transmitter Differential Input Voltage

VDT

0.5

 

2.4

V

1

Transmitter Disable Input-High

VDISH

2

 

VCC+0.3

V

 

Transmitter Disable Input-Low

VDISL

0

 

0.8

V

 

Transmitter Fault Pull up Resistor

RTX_FAULT

4.7

 

10

kΩ

2

Transmitter Fault Output-High

VTXFH

2

 

VCC+0.3

V

2

Transmitter Fault Output-Low

VTXFL

0

 

0.8

V

2

Receiver

 

 

 

 

 

 

Receiver Differential Output Voltage

VDR

0.35

 

2

V

3

Receiver LOS Load

RRXLOS

4.7

 

10

kΩ

2

LOS Output Voltage-High

VLOSH

2

 

VCC+0.3

V

2

LOS Output Voltage-Low

VLOSL

0

 

0.8

V

2

Output Dara Rise / Fall Time

tr / tf

 

 

350

psec

4

Notes:

1.Internally AC coupled and terminated to 150Ohm differential load.

2.Pull up to VCC on host Board

3.Internally AC coupled, but requires a 150Ohm differential termination at or internal to Serializer/ Deserializer.

4.These are 20%~80% values.

2

2008/01

 

Rev. 0A

DELTA ELECTRONICS, INC.

www.deltaww.com

Page 2
Image 2
Delta Electronics GBIC-1250B5QR Absolute Maximum Ratings, Recommended Operating Conditions, Transmitter, Receiver, Symbol