THERMAL CONSIDERATIONS

THERMAL CONSIDERATIONS

Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer.

Hence, the choice of equipment to characterize the thermal performance of the power module is a wind tunnel.

Thermal Testing Setup

Delta’s DC/DC power modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted.

The following figure shows the wind tunnel characterization setup. The power module is mounted on a test PWB and is vertically positioned within the wind tunnel. The space between the neighboring PWB and the top of the power module is constantly kept at 6.35mm (0.25’’).

Thermal Derating

Heat can be removed by increasing airflow over the module. The module’s maximum case temperature is +105°C. To enhance system reliability, the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit may be affected.

THERMAL CURVES

FACING PWB

PWB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODULE

Figure 21: Hot spot temperature measured point

 

 

 

 

*The allowed maximum hot spot temperature is defined at 105

 

 

 

 

 

 

*The over-temperature shutdown is 117

 

 

 

 

 

 

 

 

 

 

H48SV05030(Standard) Output Current vs. Ambient Temperature and Air Velocity

 

 

 

 

Output Current(A)

 

@ Vin = 48V (Either Orientation, no Heat sink)

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR VELOCITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AND AMBIENT

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEASURED BELOW

50.8 (2.0”)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE MODULE

25

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR FLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

Natural

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Convection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

100LFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200LFM

 

 

 

 

 

 

 

 

 

 

 

 

 

12.7 (0.5”)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

300LFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)

 

400LFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

500LFM

 

 

 

 

 

 

 

 

 

 

 

 

Figure 20: Wind Tunnel Test Setup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600LFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

25

30

35

40

45

50

55

60

65

70

75

80

85

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient Temperature ()

Figure 22: Output current vs. ambient temperature and air velocity (Vin=48V, transverse Orientation, no heat sink)