Ignition Coil

IGT001 Type

Features

Via the system-provided input voltage 230-240V, the high voltage coil is stimulated

and gives the voltage output between 14KVo-p & 25KVo-p to start up the ignition system of the gas furnance or the molecule ozonization of air cleaning M/C.

Applications

Gas Igniter

Oil Igniter

Air Cleaner

Electronic Ozonizer

Mechanical Dimension: Unit: mm

23.8

0.5

a

b

 

25.0 Max.

1

2

1.2

 

1

2

 

Schematic :

1

H.V.

a

PRI

SEC

2

b

33.0 Max.

29.0 Max.

4.0 0.5

25.0 0.5

Electrical Characteristics:

AT 25oC, 65%RH, INDUCTANCE TESTED@1KHz/1V

PART NO.

IGT-001

PRIMARY

INDUCTANCE (uH)

26.725%

SECONDARY

PRIMARY

SECONDARY

WEIGHT

INDUCTANCE (mH)

DCR (m ) MAX.

DCR ( ) MAX.

 

 

 

 

 

94.0 25%

65

165

38g

 

 

 

 

oo

Operation temperature: -40C to +105C

oo

Storage temperature: -20C to +85C Input voltage: 240 Vdc

No-load voltage: 14KV min.

Insulated with epoxy resin

Recommended Circuit:

+

 

 

 

 

SW1

 

 

 

 

SW2

 

 

 

 

 

DC

 

 

1

 

 

 

 

 

 

C1

 

 

 

 

 

 

-

 

 

 

SUPPLY

2

 

 

 

 

2.2nf

 

 

 

 

240 Vdc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T1

b

a

50pf

C2 OUTPUT

DELTA ELECTRONICS, INC.

(TAOYUAN PLANT CPBG) 252, SAN YING ROAD, KUEISAN INDUSTRIAL ZONE, TAOYUAN SHIEN, 333, TAIWAN, R.O.C.

TEL: 886-3-3591968; FAX: 886-3-3591991

http://www.deltaww.com

69

Page 1
Image 1
Delta Electronics manual Ignition Coil, IGT001 Type