LCP-10G3B4EDR 
Timing parameters for SFP+ management
| 
 | 
 | Parameter | 
 | 
 | Symbol | 
 | Min. | 
 | Max. | 
 | Unit | 
 | Note | 
 | |
| 
 | TX_DISABLE Assert time | t_off | 
 | 
 | 10 | 
 | µsec | 1 | 
 | ||||||
| 
 | TX_DISABLE Negate time | 
 | t_on | 
 | 
 | 
 | 2 | 
 | msec | 
 | 2 | 
 | |||
| 
 | Time | to | initialize | t_2w_start_up | 
 | 
 | 300 | 
 | msec | 3 | 
 | ||||
| 
 | interfase | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | Time to initialize | 
 | 
 | t_start_up | 
 | 
 | 
 | 300 | 
 | msec | 
 | 4 | 
 | ||
| 
 | Time | to | initialize | cooled | t_start_up_cooled | 
 | 
 | 90 | 
 | sec | 4 | 
 | |||
| 
 | module | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | Time to Power Up to Level 2 | 
 | t_power_level2 | 
 | 
 | 
 | 300 | 
 | msec | 
 | 5 | 
 | |||
| 
 | Time to Power Down from | T_power_down | 
 | 
 | 300 | 
 | msec | 6 | 
 | ||||||
| 
 | Level 2 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | TX_Fault assert | 
 | 
 | TX_Fault_on | 
 | 
 | 
 | 1 | 
 | msec | 
 | 7 | 
 | ||
| 
 | TX_Fault | assert for | cooled | TX_Fault_on | 
 | 
 | 50 | 
 | msec | 7 | 
 | ||||
| 
 | module | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | TX_Fault Reset | 
 | 
 | t_reset | 
 | 10 | 
 | 
 | 
 | µsec | 
 | 8 | 
 | ||
| 
 | Module Reset | 
 | 
 | t_module_reset | 
 | 
 | 
 | TBD | 
 | msec | 
 | TBD | 
 | ||
| 
 | RS0, RS1 rate select timing | 
 | t_RS0_FC, | 
 | 
 | 
 | 500 | 
 | µsec | 
 | 9 | 
 | |||
| 
 | for FC | 
 | 
 | 
 | RS1_FC | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | RS0, | RS1 | rate select | timing | t_RS0, t_RS1 | 
 | 
 | 10 | 
 | msec | 9 | 
 | |||
| 
 | non FC | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | RX_LOS assert delay | 
 | 
 | t_los_on | 
 | 
 | 
 | 100 | 
 | µsec | 
 | 10 | 
 | ||
| 
 | RX_LOS negate delay | 
 | 
 | t_los_off | 
 | 
 | 100 | 
 | µsec | 11 | 
 | ||||
Notes:
1)Rising edge of TX_Disable to fall of output signal below 10% of nominal.
2)Falling edge of TX_Disable to rise of output signal above 90% of nominal. This only applies in normal operation, not during start up or fault recovery.
3)From power on or negation of TX_Disable.
4)From power on or TX_Disable negated during power up, or TX_Fault recovery, until 
5)From falling edge of stop bit enabling power level 2 until 
6)From falling edge of stop bit disabling power level 2 until module is within power level 1 requirements.
7)From Occurrence of fault to assertion of TX_Fault.
8)Time TX_Disable must be held High to reset TX_Fault.
9)From assertion till stable output.
10)From Occurrence of loss of signal to assertion of LOS
11)From Occurrence of presence of signal to negation of RX_LOS.
| 10 | Revision: 0B | 
| 
 | 2008/9/5 | 
| DELTA ELECTRONICS, INC. | www.deltaww.com | 