LCP-10G3B4EDR

Timing parameters for SFP+ management

 

 

Parameter

 

 

Symbol

 

Min.

 

Max.

 

Unit

 

Note

 

 

TX_DISABLE Assert time

t_off

 

 

10

 

µsec

1

 

 

TX_DISABLE Negate time

 

t_on

 

 

 

2

 

msec

 

2

 

 

Time

to

initialize

2-wire

t_2w_start_up

 

 

300

 

msec

3

 

 

interfase

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time to initialize

 

 

t_start_up

 

 

 

300

 

msec

 

4

 

 

Time

to

initialize

cooled

t_start_up_cooled

 

 

90

 

sec

4

 

 

module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time to Power Up to Level 2

 

t_power_level2

 

 

 

300

 

msec

 

5

 

 

Time to Power Down from

T_power_down

 

 

300

 

msec

6

 

 

Level 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TX_Fault assert

 

 

TX_Fault_on

 

 

 

1

 

msec

 

7

 

 

TX_Fault

assert for

cooled

TX_Fault_on

 

 

50

 

msec

7

 

 

module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TX_Fault Reset

 

 

t_reset

 

10

 

 

 

µsec

 

8

 

 

Module Reset

 

 

t_module_reset

 

 

 

TBD

 

msec

 

TBD

 

 

RS0, RS1 rate select timing

 

t_RS0_FC,

 

 

 

500

 

µsec

 

9

 

 

for FC

 

 

 

RS1_FC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS0,

RS1

rate select

timing

t_RS0, t_RS1

 

 

10

 

msec

9

 

 

non FC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RX_LOS assert delay

 

 

t_los_on

 

 

 

100

 

µsec

 

10

 

 

RX_LOS negate delay

 

 

t_los_off

 

 

100

 

µsec

11

 

Notes:

1)Rising edge of TX_Disable to fall of output signal below 10% of nominal.

2)Falling edge of TX_Disable to rise of output signal above 90% of nominal. This only applies in normal operation, not during start up or fault recovery.

3)From power on or negation of TX_Disable.

4)From power on or TX_Disable negated during power up, or TX_Fault recovery, until non-cooled power level 1 part (or non-cooled power level 2 part already enabled at power level 2 for TX_Fault recovery) is fully operational.

5)From falling edge of stop bit enabling power level 2 until non-cooled module is fully operational.

6)From falling edge of stop bit disabling power level 2 until module is within power level 1 requirements.

7)From Occurrence of fault to assertion of TX_Fault.

8)Time TX_Disable must be held High to reset TX_Fault.

9)From assertion till stable output.

10)From Occurrence of loss of signal to assertion of LOS

11)From Occurrence of presence of signal to negation of RX_LOS.

10

Revision: 0B

 

2008/9/5

DELTA ELECTRONICS, INC.

www.deltaww.com

Page 10
Image 10
Delta Electronics LCP-10G3B4EDR manual Timing parameters for SFP+ management, Parameter Symbol Min Max Unit, Tbd, RS1FC