 | State/ Control Bits | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | Byte | 
 | Bit | 
 | Name | Description | 
 | |
| 110 | 7 | Tx Disable State | Digital state of the Tx disable input pin | ||||||
| 
 | 
 | 110 | 
 | 6 | Soft Tx Disable | Read/ Write bit that allow software disable of laser | 
 | ||
| 110 | 5 | Reserved | 
 | 
 | 
 | ||||
| 
 | 
 | 110 | 
 | 4 | Rate Select State | Rate Select State | 
 | ||
| 110 | 3 | Soft Rate Select | Software Rate Select State | ||||||
| 
 | 
 | 110 | 
 | 2 | Tx Fault | Digital state of the Tx fault output pin | 
 | ||
| 110 | 1 | LOS | Digital state of the LOS output pin. | ||||||
| 
 | 
 | 110 | 
 | 0 | Data_Ready_Bar | NA | 
 | 
 | |
| 7) | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | Optional Set of Alarm and Warning | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | Byte | 
 | Bit | 
 | Name | Description | 
 | |
| 112 | 7 | Temp High Alarm | Set when internal temperature exceeds high alarm level | ||||||
| 112 | 6 | Temp Low Alarm | Set when internal temperature is below low alarm level | ||||||
| 
 | 
 | 112 | 
 | 5 | Vcc High Alarm | Set when internal supply voltage exceeds high alarm level | 
 | ||
| 
 | 
 | 112 | 
 | 4 | Vcc Low Alarm | Set when internal supply voltage is below low alarm level | 
 | 
 | |
| 112 | 3 | Tx Bias High Alarm | Set when Tx Bias current exceeds high alarm level | ||||||
| 112 | 2 | Tx Bias Low Alarm | Set when Tx Bias current is below low alarm level | ||||||
| 
 | 
 | 112 | 
 | 1 | Tx Power High Alarm | Set when Tx output power exceeds high alarm level | 
 | ||
| 
 | 
 | 112 | 
 | 0 | Tx Power Low Alarm | Set when Tx output power is below low alarm level | 
 | 
 | |
| 113 | 7 | Rx Power High Alarm | Set when received power exceeds high alarm level | ||||||
| 113 | 6 | Rx Power Low Alarm | Set when received power is below low alarm level | ||||||
| 
 | 
 | 113 | 
 | Reserved | 
 | 
 | 
 | ||
| 116 | 7 | Temp High Warning | Set when internal temperature exceeds high warning level | ||||||
| 116 | 6 | Temp Low Warning | Set when internal temperature is below low warning level | ||||||
| 
 | 
 | 116 | 
 | 5 | Vcc High Warning | Set when internal supply voltage exceeds high warning level | 
 | ||
| 
 | 
 | 116 | 
 | 4 | Vcc Low Warning | Set when internal supply voltage is below low warning level | 
 | 
 | |
| 116 | 3 | Tx Bias High Warning | Set when Tx Bias current exceeds high warning level | ||||||
| 116 | 2 | Tx Bias Low Warning | Set when Tx Bias current is below low warning level | ||||||
| 
 | 
 | 116 | 
 | 1 | Tx Power High Warning | Set when Tx output power exceeds high warning level | 
 | ||
| 
 | 
 | 116 | 
 | 0 | Tx Power Low Warning | Set when Tx output power is below low warning level | 
 | 
 | |
| 117 | 7 | Rx Power High Warning | Set when received power exceeds high warning level | ||||||
| 117 | 6 | Rx Power Low Warning | Set when received power is below low warning level | ||||||
| 
 | 
 | 117 | 
 | Reserved | 
 | 
 | 
 | ||
Digital Diagnostic Monitor Accuracy
| 
 | Parameter | Typical Value | 
 | Note | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | Transceiver Temperature | ± 3℃ | 1 | 
 | |
| 
 | Power Supply Voltage | ± 3% | 
 | 2 | 
 | 
| 
 | TX Bias Current | ± 10% | 
 | 
 | 
 | 
| 
 | TX Optical Power | ± 1.5dB | 
 | 
 | 
 | 
| 
 | RX Optical Power | ± 3dB | 
 | 
 | 
 | 
| Notes: | 
 | 
 | 
 | 
 | |
| 1) Temperature is measured internal to the transceiver | 
 | 
 | 
 | ||
| 2) Voltage is measured internal to the transceiver | 
 | 
 | 
 | 
 | |
| 
 | 
 | 14 | 
 | Revision: 0B | |
| 
 | 
 | 
 | 2008/9/5 | ||
| DELTA ELECTRONICS, INC. | 
 | 
 | www.deltaww.com | ||