SFP timing parameters for SFP management
| Parameter | Symbol | Min. | Max. | Unit | Unit Conditions | 
| TX_DISABLE Assert | t_off | 
 | 10 | 
 | Time from rising edge of TX_DISABLE to | 
| 
 | µsec | when the optical output falls below 10% of | |||
| time | 
 | ||||
| 
 | 
 | 
 | 
 | nominal | |
| 
 | 
 | 
 | 
 | 
 | |
| TX_DISABLE | t_on | 
 | 1 | msec | Time from falling edge of TX_DISABLE to | 
| 
 | when the modulated optical output rises | ||||
| Negate time | 
 | ||||
| 
 | 
 | 
 | 
 | above 90% of nominal | |
| 
 | 
 | 
 | 
 | 
 | |
| Time to initialize, | t_init | 
 | 300 | msec | From power on or negation of TX_Fault using | 
| including reset of | 
 | ||||
| TX_FAULT | 
 | 
 | 
 | 
 | TX Disable. | 
| 
 | 
 | 
 | 
 | 
 | |
| TX Fault Assert | t_fault | 
 | 100 | µsec | Time from fault to TX fault on. | 
| Time | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | |
| TX_DISABLE to | t_rest | 10 | 
 | µsec | Time TX Disable must be held high to reset | 
| reset | 
 | TX_Fault | |||
| LOS Assert Time | t_loss_on | 
 | 100 | µsec | Time from LOS state to Rx LOS assert | 
| LOS Deassert Time | t_loss_off | 
 | 100 | µsec | Time from  | 
| Serial ID Clock Rate | f_serial_clock | 
 | 100 | kHz | 
 | 
| 8 | Jan. 2008 | 
| 
 | Rev. 0B | 
| DELTA ELECTRONICS, INC. | www.deltaww.com | 