LCP-2488A4EDRxM

SFP timing parameters for SFP management

Parameter

Symbol

Min.

Max.

Unit

Note

TX_DISABLE Assert time

t_off

 

10

μsec

1

TX_DISABLE Negate time

t_on

 

1

msec

2

Time to initialize, including

t_init

 

300

msec

3

reset of TX_FAULT

 

 

 

 

 

 

TX Fault Assert Time

t_fault

 

100

μsec

4

TX_DISABLE to reset

t_rest

10

 

μsec

5

LOS Assert Time

t_loss_on

 

100

μsec

6

LOS Deassert Time

t_loss_off

 

100

μsec

7

Serial ID Clock Rate

f_serial_clock

 

100

kHz

 

Notes:

1)Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal.

2)Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal.

3)From power on or negation of TX_Fault using TX Disable.

4)Time from fault to TX fault on.

5)Time TX Disable must be held high to reset TX_Fault

6)Time from LOS state to Rx LOS assert

7)Time from non-LOS state to Rx LOS deassert

8

Nov., 2006

 

Rev. 0A

DELTA ELECTRONICS, INC.

www.deltaww.com

Page 8
Image 8
Delta Electronics LCP-2488A4EDRxM specifications SFP timing parameters for SFP management, Parameter Symbol Min Max Unit