LCP-2488A4EDRxM

1) Temperature is measured internal to the transceiver.

 

 

 

 

2) Voltage is measured internal to the transceiver.

 

 

 

 

Regulatory Compliance

 

 

 

 

 

 

 

 

 

 

 

Test Item

Reference

Qty’

 

Evaluation

 

(#1)

 

FCC Class B

 

 

 

 

Electromagnetic Interference

 

 

 

 

EMC

EN 55022 Class B

5

 

 

 

 

 

CISPR 22

 

 

 

 

 

 

 

 

 

 

(#2) Immunity

EN 61000-4-3

5

 

 

 

Radio Frequency

 

 

 

IEC 1000-4-3

 

 

 

Electromagnetic Field

 

(1) Satisfied with electrical characteristics of

 

 

 

 

(#3) Immunity

 

 

 

EN 61000-4-2

 

 

product spec.

 

Electrostatic Discharge to the

 

 

 

IEC 1000-4-2

5

 

 

 

Duplex SC Receptacle

 

 

 

IEC 801.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2) No physical damage

 

(#4) Electrostatic Discharge to

 

 

 

 

 

 

 

the Electrical Pins

MIL-STD-883C

 

 

 

 

 

 

 

 

 

 

 

 

Method 3015.4

 

 

 

 

 

 

EIAJ#1988.3.2B

5

 

 

 

 

 

Version 2,

 

 

 

 

 

 

Machine model

 

 

 

 

 

 

 

 

 

 

Ordering information for SFP modules

 

 

 

 

LCP-2488X1X2X3X4X5X6X7

 

 

 

 

 

X1: Fiber

 

X5:

R: RoHS Compliant

A: Multi-mode 850nm

 

 

 

 

X2: Power Supply Voltage and SD Level

X6: Temperature

4: 3.3V, TTL SD Level

 

 

Blank: -5 to +70 degree C

 

 

 

 

 

H: -10 to +85 degree C

 

 

 

 

 

T: -40 to +85 degree C

X3: Distance

E: 300m

X4: Digital Diagnostic Function

D: DDM series, with digital diagnostic function

X7: Rate

Blank: single-rate(2488Mbps)

M: Multi-rate

13

Nov., 2006

 

Rev. 0A

DELTA ELECTRONICS, INC.

www.deltaww.com

Page 13