Installation & User Manual

June 2013

Ed 19UK

 

 

Intrinsically Safe Installation

The MAS2600 is designed for use in an approved intrinsically safe installation. The amplifier is fitted with a label describing the IS category:

S/N: XXXXXX-YYYY

DEMKO 11 ATEX 146506X IECEx ULD 10.0013X

Ui: 29V Ii: 93 mA Li: 20µH Ci: 60 nF Pi: 0.68 W

II 2(1) G

Ex ia IIC T4 Tamb.: -20 to +80 °C

Damcos A/S, Aaderupvej 41,DK-4700, Naestved

Where

 

 

S/N

:

serial number – production year.

 

:

Ex identification according to guideline 94/9/EC (ATEX).

II

:

other aria than mines.

2(1)

:

sensor mounted in zone 0 and amplifier in zone 1

Ex ia

:

denotes the type of protection intrinsic safety , i.e. the system is incapable of causing

 

 

ignition in normal operation or with any combination of up to two faults applied. This

 

 

category will be adequate for use in zone 0, 1 and 2.

IIC

:

denotes the group of gases.

T4

:

denotes the maximum surface temperature classification specified (T4: 135 °C).

Tamb

:

denotes the minimum and maximum ambient temperature for the amplifier box

permitted by the certificate.

DEMKO 11 ATEX 146506X:

The ATEX Certificate No 146506 is issued by DEMKO 201 with remarks. Inmetro:

Inmetro Certificate No. UL BR 12.0116X issued by UL do Brazil

Relevant intrinsic safety certificates to be supplied with the system units.

The certification of electric apparatus as intrinsically safe requires the apparatus to be designed and tested in accordance with approved drawings and the apparatus to be installed in accordance with approved block schematic diagrams.