Installation & User Manual

Ed 19UK

Technical Specifications

Transducer Ranges:

Gauge: 0-3.5 / 0-7 / 0-16 / 0-35 m H2O.

Absolute:

0-20.394 / 0-35.690 m H2O.

Programmable Measuring Ranges:

Each transducer range is programmable in 8 steps.

Accuracy:

±0.25% F.S. at 20°C.

Stability:

Max. ± 0.1% / Year.

TEB (Total Error Band):

± 2.0% F.S. at -20 to +80°C.

EMC immunity influence < ±0.5%FS

Overload Capability:

Min. 4 x transducer range with no changes in calibration.

6 x transducer range burst pressure.

Built-in Temperature Sensor Pt100:

Optional.

Power Supply:

The Power Supply can vary from 17-33 VDC. Permissible load resistance is shown graphically below. Calculation formula:

ULoop -17V

Rloop max. (Kohm) = 25mA

Max. load resistance at various power supply

(ohm)

700

 

 

 

 

 

600

 

 

 

 

 

500

 

 

 

 

 

resistance

400

 

 

 

 

 

300

 

 

 

 

 

200

 

 

 

 

 

100

 

 

 

 

 

0

 

 

 

 

 

17

20

23

26

29

32

Load

 

Power supply (V)

 

 

 

 

Page 4 of 28

June 2013

Output Current:

4-20 mA DC, loop powered 2-wire system.

Current Limiting:

Max:

25 mA

Sensor Materials:

Housing: Titanium Grade 2

Diaphragm: Titanium Grade 4

Operating Temperature Ranges:

 

Transducer:

-20 to +125°C

Standard cable:

-20 to +

80°C

High temperature cable:

-20 to +125°C

Amplifier:

-40 to +

85°C

Protection Class:

 

Transducer:

IP 68

Amplifier:

IP 56

Intrinsic Safety:

Ex ia IIC T4 compliant.

Max. 75 m cable between transducer and transmitter amplifier.

Transmitter dimensions

Amplifier box:

 

110.0

55.0

 

98.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2600 SERIES

 

 

 

 

4-20 mA TWO WIRE TRANSMITTER

75.0

4 pcs. ø4.5

45.0

x EEX ia

C T5

S/N: 2600

 

CERTIFICATE REF.: 90-C.95948 Tamb.: -40 to +85 °C

 

Lint = 20 uH

Cint = 10 nF

Umax = 33 V

IK=< 45 mA

 

 

 

 

 

MARINE AUTOMATION DENMARK

 

 

 

 

 

 

 

 

 

PG11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/8" NPT

cable gland

 

Use 4x20mm bolts and nuts

 

 

 

 

 

for suspension on a 4mm

 

 

vent fitting

 

thick surface

Transducer:

3.06-core vented cable, ø8.0

 

 

 

 

 

 

30.0

 

 

 

25.0

 

 

 

 

 

 

 

 

 

 

 

 

 

120.0

Front view

 

Page 4
Image 4
Emerson MAS 2600 user manual Technical Specifications