Delta Electronics LCP-8500A4EDR manual Absolute Maximum Ratings, Recommended Operating Conditions

Models: LCP-8500A4EDR

1 14
Download 14 pages 1.44 Kb
Page 2
Image 2
Absolute Maximum Ratings

Preliminary

LCP-8500A4EDR

Absolute Maximum Ratings

Parameter

Symbol

Min.

Storage Temperature

TS

-40

Supply Voltage

VCC

0

Relative Humidity

RH

5

Typ.

Max.

Unit

Note

85

ºC

 

4V

95 %

Recommended Operating Conditions

Parameter

Symbol

Min.

Case Operating Temperature

TC

-5

Supply Voltage

VCC

3.135

Data Rate

 

 

Typ.

8.5

Max.

Unit

Note

70

ºC

 

3.465

V

 

9

Gbps

 

Electrical Characteristics

(VCC=3.135V to 3.465V)

 

 

 

Parameter

Symbol

Min.

Typ.

Total Supply Current

ICC

 

180

Transmitter

 

 

 

Differential Input Voltage

Vin,pp

120

 

Data Input Rise/Fall Time

 

15

 

Transmitter Disable Input-High

VDISH

2

 

Transmitter Disable Input-Low

VDISL

0

 

Transmitter Fault Output-High

VTXFH

2

 

Transmitter Fault Output-Low

VTXFL

0

 

Receiver

 

 

 

Differential Output Voltage

Vout,pp

300

 

Data Output Rise/Fall Time

 

 

 

LOS Output Voltage-Low

VLOSH

2

 

LOS Output Voltage-High

VLOSL

0

 

RS0, RS1

VIL

-0.3

 

VIH

2.0

 

 

 

Notes:

1.Internally AC coupled and terminated to 100 Ohm differential load.

2.These are 20%~80% values.

Max.

Unit

Note

300

MA

 

 

 

 

1000

mVppd

1

40

Ps

2

VCC+0.3

V

 

0.8V

VCC+0.3

V

0.8V

1000

mVppd

3

45

Ps

1

VCC+0.3

V

 

0.8V

0.8V 4

Vcc+0.3 V

3.Internally AC coupled, but requires a 100 Ohm differential termination at or internal to Serializer/ Deserializer.

4.Shall be pulled low to VeeT with a 30k ohms resistor in the module.

2

2008/7/16

 

Rev. 0A

DELTA ELECTRONICS, INC.

www.deltaww.com

Page 2
Image 2
Delta Electronics LCP-8500A4EDR Absolute Maximum Ratings, Recommended Operating Conditions, Electrical Characteristics