Delta Electronics Q48SR manual Output voltage noise and ripple measurement test setup

Models: Q48SR

1 14
Download 14 pages 61.93 Kb
Page 6
Image 6

ELECTRICAL CHARACTERISTICS CURVES

Figure 13: Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 12µH source impedance and 33µF electrolytic capacitor (500 mA/div).

Figure 14: Input reflected ripple current, is, through a 12µH source inductor at nominal input voltage and rated load current (5 mA/div).

Copper Strip

 

 

 

Vo(+)

 

 

 

10u

1u

SCOPE

RESISTIVE

 

LOAD

 

 

 

Vo(-)

 

 

 

Figure 15: Output voltage noise and ripple measurement test setup

Figure 16: Output voltage ripple at nominal input voltage and

rated load current (20 mV/div). Load capacitance: 1µF ceramic

capacitor and 10µF tantalum capacitor. Bandwidth: 20 MHz. Scope measurement should be made using a BNC cable (length shorter than 20 inches). Position the load between 51 mm to 76 mm (2 inches to 3 inches) from the module.