3.0Equipment Required
3.1(1) 0 ~ 80 V @ 0 ~10 A Power Supply (Chroma
3.2(1) 4 Channel 150 MHz Oscilloscope, (1) 1× scope probe, (1) 10× scope probe (Yokogama DL 1540C or Equivalent)
3.3(1) 4 1/2 Digital Multimeter (DVM3) (HP34401A or Equivalent)
3.4(2) 3 1/2 Digital Multimeter (DVM1 and DVM2) (FLUKE 45 or Equivalent)
3.5(1) 300W Electronic or Resistive Load (Chroma 6304)
4.0Equipment Set-Up and Description
4.1Connect one wire from the “+” lead of the Power Supply (Item 3.1) to the “10A” of the DVM1 (Item 3.4). Then connect one wire from the “Common” of the DVM1 to the
“Vin +” pin of the Evaluation Board.
4.2Connect one wire from the
4.3Connect the plus “+” and minus
4.4Connect the plus “+” and minus
4.5Connect a BNC cable (length less than 20 inches) from BNC1 of the Evaluation Board to Channel 1 of the oscilloscope (item 3.2).
4.6Connect a BNC cable (length less than 20 inches) from BNC2 of the Evaluation Board to Channel 2 of the oscilloscope (item 3.2).
4.7Connect the Positive and Negative power leads of the Electronic load (assuring correct polarity), or a resistive load to the Evaluation Board output terminal pin (“Vout +” for positive power lead and “Vout
2