Delta Electronics Series 240W manual Electrical Characteristics Curves

Models: Series 240W

1 11
Download 11 pages 34.84 Kb
Page 6
Image 6
Figure 14: Output voltage noise and ripple measurement test

ELECTRICAL CHARACTERISTICS CURVES

Figure 12: Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 12µH source impedance and 47µF electrolytic capacitor (100 mA/div, 2us/div).

Figure 13: Input reflected ripple current, is, through a 12µH source inductor at nominal input voltage and rated load current (20 mA/div, 20us/div).

Vo(+)

Vo(-)

Copper Strip

10u

1u

SCOPE

RESISTIVE

 

LOAD

 

 

 

Figure 14: Output voltage noise and ripple measurement test

Figure 15: Output voltage ripple at nominal input voltage and

setup.

rated load current (50 mV/div, 2us/div). Load capacitance: 1µF

 

ceramic capacitor and 10µF tantalum capacitor. Bandwidth: 20

 

MHz. Scope measurements should be made using a BNC cable

 

(length shorter than 20 inches). Position the load between 51

 

mm to 76 mm (2 inches to 3 inches) from the module.

DS_E48SB12020_05222008

6

Page 6
Image 6
Delta Electronics Series 240W manual Electrical Characteristics Curves, Output voltage noise and ripple measurement test