Desa 000) 26 Trouble- Shooting, Observed Fault, Possible Cause, Remedy, See Pump Pressure

Models: 000) 26 000) 20

1 60
Download 60 pages 3.47 Kb
Page 9
Image 9
TROUBLE- SHOOTING

TROUBLE- SHOOTING

WARNING

WARNING ICON

G 001

Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

Heater ignites, but burner control shuts off heater after a short period of time.

POSSIBLE CAUSE

Wrong pump pressure

Dirty air output, air intake, and lint filters

Dirty fuel filter

Dirt in nozzle

Dirty photocell lens

Bad burner control

REMEDY

See Pump Pressure Adjustment, page 13.

See Air Output, Air Intake

and Lint Filters, page 13.

See Fuel Filter, page 10. See Nozzle, pages 14 and 15. Clean photocell lens. Replace burner control.

Heater will not ignite, but motor runs for a short period of time.

Wrong pump pressure

See Pump Pressure

 

Adjustment, page 13.

Carbon deposits on spark

See Spark Plug, pages 11

plug and/or improper gap

and 12.

Dirty fuel filter

See Fuel Filter, page 10.

Dirt in nozzle

See Nozzle, pages 14 and 15.

Water in fuel tank

Drain and flush fuel tank

 

with clean kerosene. See

 

Storing, Transporting, or

 

Shipping, page 8.

WARNING ICON

G 001 WARNING: High voltage!

 

Electronic ignitor not

Make sure electronic

 

grounded (earthed)

ignitor mounting is tight.

 

Bad electronic ignitor

Replace electronic

 

 

ignitor.

 

 

 

Motor does not start

Burner control not reset

Reset burner control

when heater is

 

button, see Figures 5

plugged in, fan

 

and 6, page 7.

rotates slowly or

Binding pump rotor

If fan is hard to turn, see

 

does not turn.

Pump Rotor, page 16.

 

9

102748

Page 9
Image 9