4
INSTALLATION OPERATION
To Start Heater
INSTALLATION
WARNING: Review and understand the warnings in the Safety Information section, page 2. They are needed to safely operate this heater. Follow all local codes when using this heater.
WARNING: Test all gas piping and connections for leaks after installation or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
1.Provide propane supply system (see Propane Supply, page 3).
2.Connect fuel gas fitting on hose/regulator assembly to pro- pane tank(s). Turn fuel gas fitting counterclockwise into threads on tank. Tighten firmly using a wrench. IMPORTANT: Tighten regulator with vent pointing down. Pointing vent down pro- tects regulator from weather damage.
3.Connect hose to the valve inlet. Tighten firmly using a wrench. You must use the regulator supplied with heater even if pro- pane tank has one.
4.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly,
5.Check all connections for leaks. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak that must be corrected.
6.Close propane supply valve.
| Fuel Gas Fitting |
Propane |
|
Supply Valve | Hose |
| Regulator |
| Vent |
| (pointing down) |
| Propane Tank |
Valve Inlet
OFF |
|
LO | HI |
| |
MED |
|
Hose
Figure 3 - Hose and Valve Inlet
OPERATION
WARNING: Review and understand the warnings in the Safety Information section, page 2. They are needed to safely operate this heater. Follow all local codes when using this heater.
TO START HEATER
1.Follow all installation, ventilation, and safety information.
2.Locate heater on stable and level surface. Make sure strong drafts do not blow on heater.
3.Make sure unit is turned off by slightly depressing and turning control knob fully clockwise to OFF.
4.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly,
5.Slightly depress and turn control knob counterclockwise to the LOW position (see Figure 4).
6.With the control knob pushed all the way in, press and release the piezo ignitor button. Keep pressing piezo ignitor button until the burner lights. Hold control knob down for a maxi- mum of 15 seconds while attempting ignition. If heater does not ignite, release control knob and wait 3 minutes before at- tempting reignition.
| Off | Low | |||
Continue Turning Knob | Position | Position | |||
Counterclockwise to |
|
|
|
|
|
MED and HI | L |
| OFF | OF | HI |
|
|
|
| F |
|
| O |
|
|
| |
| M | ED | HI | LO | ED |
|
|
|
| M |
Figure 2 - Regulator With Vent Pointing Down | Piezo Ignitor Button |
OFF
LO
MED
HI
Control Knob
Figure 4 - Control Knob and Piezo Ignitor Button Locations
For morevisit www..com