Desa BDV37N/P Inspecting Burners, Direct-Ventfireplace Natural/Propane/Lp, Operating Fireplace

Models: DDV41N/P BDV37N/P BDV41N/P B) DDV37N/P

1 42
Download 42 pages 17.61 Kb
Page 26
Image 26
OPTIONAL REMOTE

®

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

OPERATING

FIREPLACE

Continued

OPTIONAL REMOTE

OPERATION

Note: The GHRC receiver and hand- held remote control accessory must be purchased separately. (See Accessories on page 33.) Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions, page 25.

1. After lighting, let pilot flame burn for

about one minute. Turn gas control

knob on the control valve to ON posi-

tion. Turn variable control knob any-

where between HI and LO. Slide the

selector switch to the REMOTE po-

sition. Note: The burner may light if

hand-held remote ON button was on

when selector switch was last turned

off. You can now turn the burners on

and off with the hand-held remote con-

trol unit.

OPERATING

OPTIONAL BLOWER

ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.

Both the GA3700 manual blower and the DA3610T thermostatically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for CDA3610T Only: If you are using CDA3610T blower, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.

The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure

56.The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.

If your pilot assembly does not meet these requirements:

turn fireplace off (seeTo Turn Off Gas to Appliance, page 25)

seeTroubleshooting, pages 28 through 30

Thermopile

3/8" to 1/2"

Pilot Burner

IMPORTANT: Do not leave the se-

lector switch in the REMOTE posi-

tion when the pilot is not lit. This will

drain the battery.

IMPORTANT: Be sure to press the

ON/OFF button on the hand-held re-

mote control unit for up to 3 seconds

to assure proper operation.

2. Press the ON/OFF button to turn the

burners on and off. When turning

burners off, the pilot will remain lit.

IMPORTANT: To turn the pilot off,

manually turn the gas control knob

Blower Control Knob (Optional Accessory)

OFF

ON

REMOTE

OFF

ON

Selector Switch in

Remote Position

(Optional Remote

Control)

Variable Control Knob

N

 

L

 

O

 

O

I

T

F

O

H

O

 

 

F

 

 

LIP

 

 

 

 

 

 

 

Gas Control

Knob in On

Position

1/8"

Thermocouple

Piezo

Ignitor

Figure 56 - Pilot Assembly

BURNER FLAME PATTERN

on the heater to the OFF position.

Figure 55 - Setting the RSelector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.

If the vent configuration is installed incor- rectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after installation to ensure proper installation and performance.

26

105539

Page 26
Image 26
Desa BDV37N/P Inspecting Burners, Direct-Ventfireplace Natural/Propane/Lp, Operating Fireplace, Continued, Pilot Assembly