OWNER’S MANUAL

OPERATING

FIREPLACE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a quali- fied service technician. Force or at- tempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con- trol which has been under water.

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information in

 

column one.

2.

Open lower louver panel.

3.

Disconnect the wire that runs from TH

 

to TPTH from the valve.

4.

Turn off all electric power to the

 

fireplace.

5.

Push in gas control knob slightly and

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information in column one. If you don't smell gas, go to the next step.

7.The pilot is located by the main burner and should not require accessing for lighting.

8.Turn gas control knob counterclock-

wise to “PILOT”.

9.Push in gas control knob all the way and hold. Immediately light the pilot by re- peatedly depressing the piezo spark ig- nitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after sev- eral tries, turn the gas control knob to “OFF” and call your service tech- nician or gas supplier.

10.Reconnect the wire that runs from TH to TPTH from the valve.

11.Turn on all electric power to the fireplace.

12.Turn gas control knob counterclock-

wise to “ON”.

13.This valve is equipped with a HI/LO feature. Set fireplace input as desired.

14.Close lower louver panel.

TO TURN OFF GAS

TO APPLIANCE

1.Open lower louver panel.

2a. If Using Optional ON/OFF Switch:

Turn ON/OFF switch to “OFF”.

2b. If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to prevent draining battery.

Gas Control Knob Variable Control Knob

Piezo

Ignitor

IL T

IH

O

 

P

O

F

N

F

 

O

 

 

LO

3.Turn off all electrical power to the ap- pliance if service is to be performed.

4.Push in gas control knob slightly and

turn clockwise to “OFF”.

5.Close lower louver panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn gas control knob clockwise to the PILOT position.

2.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Re- placing Glass Door, page 22).

2.Follow steps 1 through 8 under Light- ing Instructions.

3.Depress gas control knob and light pi- lot with match.

4.Keep gas control knob pressed in for 30 seconds after lighting pilot. After 30 sec- onds, release gas control knob. Now fol- low steps 10 through 14, column 2.

5.Replace glass door (see Removing/Re- placing Glass Door, page 22).

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased separately (See Accessories on pages 34 and 35). Follow instructions included with the remote control.

Thermostat Control Operation

(Optional GHRCT Only) The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burners will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions.

turn clockwise

to “OFF”.

Figure 55 - Control Valve

Continued

105981

25

Page 25
Image 25
Desa BHDV34PA, BHDV34NA installation manual Operating Fireplace