® BHDV34NA, PA

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

OPERATING

FIREPLACE

Continued

1. After lighting, let pilot flame burn for

about one minute. Turn gas control

knob on the control valve to ON posi-

tion. Turn variable control knob any-

where between HI and LO. Slide the

selector switch to the REMOTE posi-

tion. Note: The burners may light if

hand-held remote ON button was on

when selector switch was last turned

off. You can now turn the burners on

and off with either optional hand-held

remote control unit.

IMPORTANT: Do not leave the se-

lector switch in the REMOTE posi-

tion when the pilot is not lit. This will

IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in auto mode. It will not re- spond immediately to the tempera- ture setting being turned up or down.

IMPORTANT: The hand-held remote control unit must be near the heater but not extremely close to it. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off.

3.Use the STATUS button on the hand- held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera- tion mode being used.

4.To turn the burners off when operat- ing in the manual mode, press the OFF button. If operating in the auto mode, press the MAN button, then press the OFF button. The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the gas control knob on the heater to the OFF position.

OPERATING

OPTIONAL BLOWER

ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.

Both the GA3700 manual blower and the DA3610T thermostatically-controlled

drain the battery.

IMPORTANT: Be sure to press the

ON/OFF buttons on the hand-held

remote control unit for up to 3 sec-

onds to assure proper operation.

GHRC Series Operation:

2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.

GHRCT Series Operation:

Blower Control Knob (Optional Accessory)

OFF

ON

REMOTE

OFF

ON

Selector Switch in Remote Position

Variable Control Knob

N

 

L

 

O

 

O

I

T

F

O

H

O

 

 

F

 

 

LIP

 

 

 

 

 

 

 

Gas Control

Knob in On

Position

blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for DA3610T Only: If you are using DA3610T blower with optional ther- mostat (wall mount or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns

2b. Select the MAN (manual) or AUTO button on the hand-held remote con- trol unit.

In manual mode, turn burners on

or off by pressing the ON or OFF

buttons on the hand-held remote

control unit.

• In auto mode, the room tempera-

ture is controlled by the thermo-

stat in the hand-held remote con-

Figure 56 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation

on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

trol unit. To increase the room tem-

perature, press the top arrow of the

TEMP button. To lower the room

temperature, press the bottom ar-

row of the TEMP button. At higher

settings the heater will run more.

Shows Temperature Setting

Allows Burners to be Turned On and Off with the Hand-Held Remote Unit.

The Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected.

HI

TEMP

MAN LO ON

AUTO OFF

STATUS

Increases Room Temperature

Decreases Room Temperature

Turns Burners On and Off

Shows Current Operation Mode

Figure 57 - Hand-Held Thermostat Remote Control Unit Selections (GHRCT Only)

26