14 | SERVICE PROCEDURES |
WIRING DIAGRAM | |
|
|
SERVICE PROCEDURES
Continued
WIRING DIAGRAM
Installing the New Assembly
CAUTION: Ignition control assembly contains electrostatic components. Handle the assembly by the edges of the printed circuit board. Do not touch any of the quick connect terminals or electronic components.
1.Align the five holes in the assembly with the five printed cir- cuit board supports in the side cover.
2.Holding the assembly by the edges of the printed circuit board, apply downward pressure until all five tabs on the printed cir- cuit board supports springlock into place. Pull up on assembly to verify this (see Figure 31).
3.Connect the nine wire leads to the ignition control assembly as shown in the wiring diagram in column 2.
Power Plug
240 V/50Hz
Brown
Blue
Photocell
Blue | Blue | White | White | Blue |
1b
ON/Off Switch
1
1a
Brown/White | Motor |
Red |
Ignitor
Black | Black |
|
|
CAUTION: Double check connections. Connect- ing ignition control assembly wrong could result in damage to the ignition control assembly and/or other components in the heater assembly.
4.Using the 5/16" nut driver or socket wrench reinstall side cover to heater. Tighten screws until snug. Do not over torque!
UnacceptableAcceptable
Figure 31 - Attaching Circuit Board to Tabs
(1) (2) | (3) (4) (N) (5) | (6) | (7) (8) |
Ignition Control
105522