ASSEMBLY

4

ASSEMBLY

VENTILATION

 

THEORY OF OPERATION

 

 

ASSEMBLY

(FOR BY100CEH AND BY150CEH MODELS ONLY)

These models are furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping carton.

Tools Needed

Medium Phillips Screwdriver

3/8" Open or Adjustable Wrench

Hammer

1.Slide axle through wheel support frame. Install wheels on axle.

IMPORTANT: When installing wheels, point extended hub of wheels toward wheel support frame (see Figure 3).

2.Place cap nuts on axle ends. Gently tap with hammer to secure.

3.Place heater on wheel support frame. Make sure air inlet end (rear) of heater is over wheels. Line up holes on fuel tank flange with holes on wheel support frame.

4.Place front handle and rear handle on top of fuel tank flange. Insert screws through handles, fuel tank flange, and wheel sup- port frame. Attach nut finger tight after each screw is inserted.

5.After all screws are inserted, tighten nuts firmly.

Front Handle

Screw

VENTILATION

(FOR BY100CEH AND BY150CEH MODELS ONLY) WARNING: Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poison- ing can occur. Provide proper fresh, outside air ven- tilation before running heater.

Provide a fresh air opening of at least 2800 square cm (three square feet) for each 30kw (100,000 Btu/Hr) rating. Provide extra fresh air if more heaters are being used.

Example: A 44kw (150,000 Btu/Hr) heater requires one of the following:

a two-car garage door [4.9 meter (16 feet) opening] raised 9 cm (3.5 inches)

a single-car garage door [2.75 meter (9 feet) opening] raised 15.25 cm (6 inches)

two, 76 cm (30 inch) windows raised 28 cm (11 inches)

THEORY OF OPERATION

The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

Hot Air

Outlet

Fuel Tank

Flange

Wheel

Support

FrameVENTILATION

Wheel Nut THEORY OF OPERATION

Cap Nut

Manual backgroundRear

Handle

Air

Inlet

Extended

Hub

Axle

The Ignition System: The ignition control assembly provides power to the ignitor. This ignites the fuel/air mixture in the combus- tion chamber.

The Flame-Out Control System: This system causes the heater to shut down if the flame goes out.

Combustion

Ignitor

 

Motor

Air Pump

Chamber

 

 

Fan

Air Intake

 

 

 

 

 

 

 

Filter

 

 

 

 

 

Clean

 

 

 

 

 

Heated

 

 

 

 

Cool

Air Out

 

 

 

 

Air In

 

 

 

 

 

Air

 

 

 

 

 

Output

 

 

 

 

 

Filter

Fuel

 

 

 

Air Line

Ignition

Nozzle

Fuel

Control

Tank

Filter

To Burner

Assembly

 

 

 

 

 

Air For

 

 

Figure 3 - Wheel and Handle Assembly

Air For Fuel

Combustion

Fuel

System

 

 

 

And Heating

Figure 4 - Cross Section Operational View

105522

Page 4
Image 4