VENT-FREE PROPANE COMPACT FIREPLACE

AIR FOR

COMBUSTION AND

VENTILATION

Continued

DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height = ____________________ cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free fireplace

 

_________________ Btu/Hr

 

 

 

 

Gas water heater*

 

_________________ Btu/Hr

Example:

 

 

 

Gas furnace

 

_________________ Btu/Hr

Gas water heater

 

30,000

Btu/Hr

Vented gas heater

 

_________________ Btu/Hr

Vent-free fireplace

+

26,000

Btu/Hr

Gas fireplace logs

 

_________________ Btu/Hr

Total

=

56,000

Btu/Hr

Other gas appliances* +

_________________ Btu/Hr

 

 

 

 

Total

=

_________________ Btu/Hr

 

 

 

 

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

___________ Btu/Hr (maximum the space can support)

___________ Btu/Hr (actual amount of Btu/Hr used)

Example: 51,200 Btu/Hr (maximum the space can support) 56,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.

B.Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7.

C.Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3 or applicable local codes.

6

105616

Page 6
Image 6
Desa CGCF26PRA installation manual AIR for Combustion Ventilation, Determining FRESH-AIR Flow for Fireplace Location

CGCF26PRA specifications

Desa CGCF26PRA is a modern heater that combines advanced technology with user-friendly features to deliver efficient warmth for home and outdoor spaces. This product is particularly known for its reliability and performance as a convection heater.

One of the standout features of the Desa CGCF26PRA is its powerful 26,000 BTU output, enabling it to effectively heat large areas quickly. This makes it an ideal choice for both residential and commercial applications, especially during the colder months when efficient heating solutions are critical. The heater is designed to operate on liquid propane, which is both cost-effective and readily available, ensuring users can keep their environments comfortably warm without breaking the bank.

In terms of technology, the Desa CGCF26PRA is equipped with an electronic ignition system that provides a reliable start-up with the push of a button. This modern feature eliminates the need for matches or lighters, enhancing convenience and safety. Additionally, the heater is built with safety features such as a safety shut-off valve, which automatically turns off the gas supply in the event of a malfunction, ensuring peace of mind for users concerned about safety.

The design of the Desa CGCF26PRA facilitates easy mobility, thanks to its lightweight construction and integrated handle. It features a compact size that allows it to fit effortlessly in various spaces, whether it's a garage, workshop, or outdoor setting. The heater also has a versatile design that complements a wide range of environments without being an eyesore.

Furthermore, the heater operates quietly, which is an essential characteristic for maintaining a comfortable atmosphere without disruptive noise. Its durable construction ensures longevity, even when subjected to regular use in demanding conditions.

In conclusion, the Desa CGCF26PRA heater stands out for its robust heating capability, modern ignition technology, safety features, portability, and quiet operation. These characteristics make it an excellent investment for anyone in need of an effective heating solution for various settings and applications.