Installing Receiver

VENT-FREE PROPANE COMPACT FIREPLACE

INSTALLATION

Continued

OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES (CGHRC Series and CGHRCT Series)

Installing Receiver

1.Remove screws.

2.Disconnect switch wires from the con- trol valve.

3.Remove switch plate (see Figure 22). Discard switch plate after removing. Save the screws.

4.Locate the battery clip mounted on the back of the receiver (see Figure 23).

5.Slide 9-volt battery (not included) through the clip.

6.Attach the terminal wires to the battery (see Figure 23).

7.Connect wires as shown in Figure 24.

8.Install remote receiver unit onto gas heater base using the two screws re- moved in step one (see Figure 24).

Screw Manual background

Switch Plate

Manual backgroundRed Wire

Black Wire

Heater Base

Figure 22 - Switch Plate and Wiring Harness

Receiver

Terminal

Wires

Battery Clip

9-Volt Battery

Figure 23 - Attaching Battery to Receiver

Remote

Receiver

Black Wire

Red Wire

 

Wire Harness*

Wires from

Valve

Black Wire

Red Wire

Figure 24 - Installing Remote Receiver

*Wire harness provided in the fireplace hardware pack.

Installing 9-Volt Battery in Hand- Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to the battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Battery Remote

Terminal CoverControl Unit

Wires

9-Volt Battery

Manual background Battery

Housing

Figure 25 - Installing Battery in Hand- Held Remote Control Unit