8

INSTALLATION

Installation Items Locating Fireplace

INSTALLATION

Continued

INSTALLATION ITEMS

Before installing fireplace, make sure you have the items listed below.

external regulator - propane/LP only (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

ground joint union

sediment trap

tee joint

pipe wrench

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 29.

Note: If desired, purchase a four-sided brass trim kit for built-in installations. See Accessories, page 29.

LOCATING FIREPLACE

WARNING: Maintain the minimum clearances shown in Figures 7 and 8. If you can, provide greater clearances from floor, ceiling, and joining wall.

You can recess firebox into the wall. You can also position fireplace in the optional cabinet or corner mantels. IMPORTANT: Only use optional cabinet or corner mantels specified in this manual. Purchase the optional mantel from your dealer (see Accessories, page 29).

WARNING: Never install the fireplace

• in a bedroom or a bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flam-

IMPORTANT: Vent-free fireplaces add moisture to the air. Although this is beneficial, installing fireplace in rooms without enough venti- lation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.

Note: When installing fireplace directly on carpeting, tile or other combustible material, other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth of the fireplace

CAUTION:Ifyouinstallthefireplaceinahomegarage

fireplace pilot and burner must be at least 18 inches above floor.

locate fireplace where moving vehicle will not hit it.

 

CEILING

 

 

36" Minimum

 

6"

 

 

Minimum

 

 

From

 

 

Sides Of

 

 

Fireplace

 

 

Left

Right

 

Side

Side

0" Minimum To Top

 

 

 

 

Surface Of Carpeting,

 

 

Tile Or Other

 

 

Combustible Material

FLOOR

Figure 7 - Mounting Clearances As Viewed From Front of Fireplace Shown Built In The Wall

CEILING

mable objects are less than 36 inches from the

Top Of

36"

 

front, top, or sides of the fireplace

• as a fireplace insert

in high traffic areas

in windy or drafty areas

Mantel Can

Be Flush

With Wall

Minimum

CAUTION: This fireplace creates warm air cur- rents. These currents move heat to wall surfaces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating fireplace where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

 

Right

0" Minimum To Top

Left

Side

 

Surface Of Carpeting,

Side

 

 

 

Tile Or Other

 

 

Combustible Material

Figure 8 - Mounting Clearances As Viewed From Front of Fireplace Shown with Optional Mantel

For..com

111044-01A

Page 8
Image 8
Desa CGCF26TN installation manual Installation Items, Locating Fireplace