Top Brass Trim
Mitered Edge

OWNER’S MANUAL

INSTALLATION

Continued

ASSEMBLING BRASS TRIM (Brass trim shipped with mantel)

1.Remove packaging from three remain- ing pieces of brass trim.

2.Locate two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 14.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 14).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 14).

6.While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other corner.

8.Set brass assembly aside for later in-

stallation.

SetSlot

Screws

Shim

3.Insert floor anchor (wings first) into hole. Tap anchor flush to floor.

4.Insert mounting screws through base and into floor anchors.

5.Tighten screws until base is firmly fas- tened to floor.

Figure 15 - Folding Anchor

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes.

CAUTION: Never connect fire- place directly to the propane/LP supply. This fireplace requires an external regulator (not sup- plied). Install the external regula- tor between the fireplace and pro- pane/LP supply.

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, fireplace regulator damage could occur. Install external regulator with

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" or greater diameter to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 17).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 17. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

A.G.A. Design-Certified

Adjusting Plate

Side Brass Trim

the vent pointing down as shown in Figure

16.Pointing the vent down protects it from freezing rain or sleet.

Manual Shutoff Valve With 1/8" NPT Tap*

Slot

Figure 14 - Assembling Brass Trim

ATTACHING WOOD BASE TO SOLID FLOOR

For attaching base to solid floors (concrete or masonry)

Note: Floor anchors and mounting screws are in hardware package. The hardware pack- age is provided with fireplace.

1.Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep.

2.Fold floor anchor as shown in Figure 15.

Propane/LP

External Regulator

Supply

 

Tank

 

Vent Pointing Down

Figure 16 - External Regulator with Vent Pointing Down

 

From

 

External

Approved Flexible

Regulator

Gas Line

(11" W.C.

 

to 14" W.C.

 

Pressure)

3" Minimum

 

Pipe Nipple

Cap Tee Joint

Sediment Trap

Figure 17 - Gas Connection

*Purchase the optional A.G.A. design-cer- tified manual shutoff valve from your dealer. See Accessories, page 22.

Continued

104278