OWNER’S MANUAL
INSTALLATION
Continued
ASSEMBLING BRASS TRIM (Brass trim shipped with mantel)
1.Remove packaging from three remain- ing pieces of brass trim.
2.Locate two adjusting plates with set screws, and two shims in the hardware packet.
3.Align shim under adjusting plate as shown in Figure 14.
4.Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 14).
5.Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 14).
6.While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.
7.Repeat steps 1 through 6 for other corner.
8.Set brass assembly aside for later in-
stallation.
SetSlot
Screws
Shim
3.Insert floor anchor (wings first) into hole. Tap anchor flush to floor.
4.Insert mounting screws through base and into floor anchors.
5.Tighten screws until base is firmly fas- tened to floor.
Figure 15 - Folding Anchor
CONNECTING TO GAS SUPPLY
WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes.
CAUTION: Never connect fire- place directly to the propane/LP supply. This fireplace requires an external regulator (not sup- plied). Install the external regula- tor between the fireplace and pro- pane/LP supply.
The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, fireplace regulator damage could occur. Install external regulator with
CAUTION: Use only new, black iron or steel pipe. Inter-
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 17).
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.
Install sediment trap in supply line as shown in Figure 17. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
A.G.A.
Adjusting Plate
Side Brass Trim
the vent pointing down as shown in Figure
16.Pointing the vent down protects it from freezing rain or sleet.
Manual Shutoff Valve With 1/8" NPT Tap*
Slot
Figure 14 - Assembling Brass Trim
ATTACHING WOOD BASE TO SOLID FLOOR
For attaching base to solid floors (concrete or masonry)
Note: Floor anchors and mounting screws are in hardware package. The hardware pack- age is provided with fireplace.
1.Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep.
2.Fold floor anchor as shown in Figure 15.
Propane/LP | External Regulator |
Supply |
|
Tank |
|
Vent Pointing Down
Figure 16 - External Regulator with Vent Pointing Down
| From |
| External |
Approved Flexible | Regulator |
Gas Line | (11" W.C. |
| to 14" W.C. |
| Pressure) |
3" Minimum |
|
Pipe Nipple | Cap Tee Joint |
Sediment Trap
Figure 17 - Gas Connection
*Purchase the optional A.G.A.
Continued
104278 | 11 |