CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.

Remove fireplace screen. Remove two

 

screws that hold fireplace screen in

 

place for shipping. These screws are

 

located near top of screen. Discard

 

screws. Lift fireplace screen up and pull

 

out to remove.

2.

Remove screws that attach branch sup-

 

port to fireplace (see Figure 18). Care-

 

fully lift up branch support and remove

 

from fireplace (see Figure 18).

3.

Route flexible gas line (provided by

 

installer) from manual shutoff valve

 

into fireplace through side or rear ac-

Screen

Shipping

Branch Screw

Support

Shoulder Screw

Flexible Gas

Line

Screen

Figure 18 - Removing Log Base Assembly From Fireplace

cess holes in outer casing. Route flex-

ible gas supply line through fireplace

access holes in outer casing.

NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 19). The flexible gas supply line con-

To Fireplace

 

 

Gas Regulator

Gas Connector

 

Flexible Gas Line from Fireplace Gas Regulator

Provided With FireplaceFlexible Gas Line from Manual Shutoff Valve Provided By Installer

Manual Shutoff Valve

To External

Regulator

nection to the manual shutoff valve should be accessible.

4.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line (see Figure 19). Con- nect flexible gas line to flexible gas line attached to gas regulator of fireplace (see Figure 19).

5.Check all gas connections for leaks. See Checking Gas Connections, page 13.

6.Replace branch support back into fire- place. Feed flexible gas line into fire- place base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reat- tach branch support to fireplace with screws removed in step 2.

Figure 19 - Attaching Flexible Gas Lines Together