Desa installation manual Mantel Clearances, Floor Clearances, Determining Minimum Mantel Clearance

Models: CGD3018N, CGD3924N, CGD3930N, CRL2718N, CCL3924N, CRL3124N, CCL3018N, CGD3924NT, CGD3018NT, CCL3924NT, CGD3930NT, CCL3018NT, CCL3930NTA

1 40
Download 40 pages 44.81 Kb
Page 9
Image 9

INSTALLATION

Continued

INSTALLATION

9

Mantel Clearances

Floor Clearances

 

 

 

Mantel Shelf

MANTEL CLEARANCES

12"

10"

8"

Underside of Mantel Shelf

In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clearances listed in Figure 7, you will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 7).

Determining Minimum Mantel Clearance When Using a Hood

6"

2 1/2"

Minimum Non-

Combustible

Material

8"

Min.

Hood

(GA6050, GA6052, and GA6053)

12"

15"

 

 

Distances to Underside of Mantel

18"

All minimum distances are in inches

Log Set

20" All Models

Top of Fireplace Opening

If minimum clearances in Figure 7 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Fig- ure 8 when using hood.

Figure 8 - Minimum Mantel Clearances When Using Hood

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the mini- mum clearances shown, you must do one of the following:

FLOOR CLEARANCES

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 9).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible floor- ing (see Figure 10).

• operate the logs only with the flue damper open

14"

Combustible Material

raise the mantel to an acceptable height

remove the mantel

Min.

Noncombustible Material

10"

8"

6"

2 1/2"

Minimum Non-

 

 

(A)

 

Combustible

 

Material

12"

 

 

 

 

 

 

8"

 

 

 

 

Mantel Shelf

18"

 

20"

22"

 

8"

 

14"

17"

 

 

 

 

Underside of

Mantel Shelf

All minimum distances are in inches

Log Set

24" 24"/30" Models

20" 18" Model

Top of Fireplace

Opening

Figure 9 - Minimum Fireplace Clearances If Installed at Floor Level

Hearth

Combustible Material

5"

Min.

Figure 10 - Minimum Fireplace Clearances Above Combustible Flooring

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 7 - Minimum Mantel Clearances Without Using Hood

For morevisit www..com

107123-01F

Page 9
Image 9
Desa installation manual Mantel Clearances, Floor Clearances, Determining Minimum Mantel Clearance