OPERATING HEATER
Continued
INSPECTING BURNER
|
| TO TURN OFF GAS TO APPLIANCE |
|
|
|
| |
|
|
| |
Shutting Off Heater | |||
1. | Turn control knob clockwise Clockwise to the PILOT position. | ||
2. | Press in control knob and turn clockwise Clockwise to the OFF position. | ||
3. | Turn off all electric power to the appliance if service is to be performed. | ||
Shutting Off Burner Only (pilot stays lit) | |||
1. | Turn control knob clockwise Clockwise to the PILOT position. |
MANUAL LIGHTING PROCEDURE
1.Remove front panel (see Figure 5, page 11).
2.Follow steps 1 through 5 under Lighting Instructions, pages 17 and 18.
3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
5.Replace front panel.
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN
Figure 17 shows a correct pilot flame pattern. Figure 18 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
Pilot Burner
Thermocouple
GOOD PILOT | GRH/OV 009 |
Figure 17 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
BAD PILOT | GRH/OV 010 |
Figure 18 - Incorrect Pilot Flame Pattern
Continued 19
100096