CHECKING GAS CONNECTIONS

CONNECTING TO GAS SUPPLY

Continued

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

Pressure

Regulator

3/8" NPT

Pipe NipplePRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Heater

Cabinet

Ground Joint Union

Manual Shutoff Valve *

From External Regulator Manual background

(11" W.C. to 14" W.C.

Pressure)

3" Minimum

Tee Joint

 

 

 

Test

Reducer

 

 

 

Bushing to

 

Gauge

 

1/8" NPT

 

 

Connection *

 

 

 

 

 

 

 

1/8" NPT

 

 

 

 

Plug Tap

 

 

 

 

Tee

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Joint

 

 

 

 

 

 

Pipe

 

 

Sediment Trap

 

 

Nipple

 

 

 

 

 

 

Cap

 

 

 

 

 

 

 

CHECKING GAS CONNECTIONS

14

Figure 13 - Gas Connection

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessory, page 28.

Manual background WARNING

Test all gas piping and connections for leaks after installation or servicing. Correct all leaks at once.

Manual background WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Manual background CAUTION

Make sure external regulator has been installed between propane/LP supply and heater. See guidelines under Connecting to Gas Sup- ply, page 13.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 Psig will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

103575