CHECKING GAS CONNECTIONS

OWNER’S MANUAL

CHECKING GAS CONNECTIONS

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM WARNING: Test all gas pip- ing and connections for leaks after installation or servicing. Correct all leaks at once.

Test Pressures In Excess Of 1/2WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

PRESSURE TESTING CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater. See guidelines under Con- necting to Gas Supply, page 8.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2

PSIG

1.

Disconnect heater and its individual

 

manual shutoff valve from gas supply

 

piping system. Pressures in excess of

 

1/2 psig will damage heater regulator.

2.

Cap off open end of gas pipe where

 

manual shutoff valve was connected.

3.

Pressurize supply piping system by ei-

 

ther using compressed air or opening

 

propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply tank to manual shutoff valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

PRESSURE TESTING

HEATER GAS

CONNECTIONS

1.Open manual shutoff valve (see Figure 14).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to control valve (see Figure 15). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 9 and 10). Check all other inter- nal joints for leaks.

7.Turn off heater (see To Turn Off Gas To Appliance, page 10).

8.Replace front panel.

Open

Manual

Shutoff

Valve OPERATING

Closed

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

FOR YOUR SAFETY WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.

This appliance has a pilot which must

 

be lighted by hand. When lighting the

 

pilot, follow these instructions ex-

 

actly.

B. BEFORE LIGHTING smell all

 

around the appliance area for gas. Be

 

sure to smell next to the floor because

 

some gas is heavier than air and will

 

settle on the floor.

 

WHAT TO DO IF YOU SMELL

 

GAS

 

Do not try to light any appliance.

 

Do not touch any electric switch;

 

 

do not use any phone in your build-

 

 

ing.

 

• Immediately call your gas supplier

 

 

from a neighbor’s phone. Follow

 

 

the gas supplier’s instructions.

 

If you cannot reach your gas sup-

 

 

plier, call the fire department.

C. Use only your hand to push in or turn

 

the gas control knob. Never use tools.

 

If the knob will not push in or turn

 

by hand, don’t try to repair it, call a

4.

Check all joints of gas supply piping

 

system. Apply mixture of liquid soap

 

and water to gas joints. Bubbles form-

 

ing show a leak.

5.

Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1.

Close manual shutoff valve (see Fig-

 

ure 14).

2.

Pressurize supply piping system by ei-

Figure 14 - Manual Shutoff Valve

Propane/LP

Supply Tank

Control

Valve

Location

Manual Shutoff

qualified service technician or gas

supplier. Force or attempted repair

may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately

call a qualified service technician to

inspect the appliance and to replace

any part of the control system and

any gas control which has been un-

der water.

ther using compressed air or opening

propane/LP supply tank valve.

Test Pressures Equal To or Less Than 1/2 PSIGManual background Valve

Figure 15 - Checking Gas Joints

Continued

101871

9

Page 9
Image 9
Desa CGP10A, CGP6 installation manual Checking Gas Connections, Operating Heater, Pressure Testing Gas Supply Piping System