Desa CGS2718N Inspecting Burners, Operating Heater, Manual Lighting Procedure, Continued

Models: CGS2718N

1 32
Download 32 pages 31.99 Kb
Page 22
Image 22
OPERATING HEATER

OPERATING HEATER

Continued

INSPECTING BURNERS

22

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, pages 20 and 21.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 on page 21.

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 21 shows a correct pilot flame pattern. Figure 22 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Thermocouple

 

Thermocouple

Pilot Burner

 

Pilot Burner

 

 

 

 

 

Figure 21 - Correct Pilot

Figure 22 - Incorrect Pilot

Flame Pattern

Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 22

turn heater off (see To Turn Off Gas to Appliance, page 21)

see Troubleshooting, pages 23 through 26

102988

Page 22
Image 22
Desa CGS2718N installation manual Inspecting Burners, Operating Heater, Manual Lighting Procedure, Continued