Desa CGS2718N Installing, Continued, Non-Combustible, Requirements for, Material Distance A

Models: CGS2718N

1 32
Download 32 pages 31.99 Kb
Page 11
Image 11
Continued

INSTALLING

Continued

Minimum Non Combustible Material Clearances

If Using Mantel

You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non combustible material behind it. Non combustible material must extend at least 8 inches up (for all models). If non combustible material is less than 12", you must install the fireplace hood acces- sory (24" model only). Even if non combustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See chart below and Figures 6 and 7 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Acces- sory for Vented Operation, page 13.

Non-Combustible

Requirements for

Material Distance (A)

Safe Installation

12" or more

Non combustible material okay.

Between 8" and 12"

24" Model: Install fireplace hood acessory (GA6050

 

or GA6052, see Accessories, page 29).

 

18" Model: Non combustable material okay.

Less than 8"

Non combustible material must be extended to at

 

least 8". See Between 8" and 12", above. If you

 

cannot extend material, you must operate heater

 

with flue damper open.

Mantel Clearances

If you meet minimum clearance between mantel shelf and top of fireplace open- ing, a hood is not required (see Figure 6).

Mantel Shelf

10"

Underside of

 

8"

 

 

Mantel Shelf

 

 

 

 

 

6"

 

 

 

 

2 1/2"

 

 

 

 

 

 

 

All minimum

 

 

 

 

distances are

 

 

 

 

in inches

Minimum Non-

(A)

 

 

 

Combustible

 

 

Log Set

 

 

 

Material

 

 

 

12"

20"

241/2" 271/2" 30"

24" Model

 

 

8"

14"

163/4" 181/2" 20"

18" Model

 

 

 

 

Top of Fireplace

 

 

 

 

Opening

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

If above minimum clearances are not met, you must have a hood. Follow

minimum clearances shown in Figure 7 when using hood.