Desa CRN30 installation manual Gas leak. See Warning

Models: CRN30

1 32
Download 32 pages 45.03 Kb
Page 21
Image 21

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when using

within burner box or on adjacent

 

furniture polish, wax, carpet

 

furniture polish, wax, carpet

walls or furniture

 

cleaner, etc., may turn into

 

cleaners or similar products

 

 

white powder residue

 

 

 

 

 

 

 

Heater produces unwanted

1.

Heater burning vapors from

1.

Ventilate room. Stop using

odors

 

paint, hair spray, glues, etc. See

 

odor causing products while

 

 

IMPORTANT statement above

 

heater is running

 

2.

Low fuel supply (propane/LP

2.

Refill supply tank

 

 

gas)

3.

Locate and correct all leaks

 

3.

Gas leak. See Warning

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, page 12)

 

 

 

 

 

Heater shuts off in use (ODS

1.

Not enough fresh air is

1.

Open window and/or door for

operates)

 

available

 

ventilation

 

2.

Low line pressure

2.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning

 

 

 

 

and Maintenance, page 18)

 

 

 

 

 

Gas odor even when control

1.

Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

2.

Control valve defective

 

tions, page 12)

 

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between con-

 

 

trol valve and burner

 

2.

Gas leak. See Warning

 

 

statement at top of page

1.Take apart gas tubing and remove foreign matter

2.Locate and correct all leaks (see Checking Gas Connec- tions, page 12)

Moisture/condensation noticed

1. Not enough combustion/ven-

1. Refer to Fresh Air for Com-

on windows

tilation air

bustion and Ventilation re-

 

 

quirements (page 5)

107883-01H

www.desatech.com

21

Page 21
Image 21