INSTALLATION
11
INSTALLATION
Continued
NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.
Installation Items Needed
Before installing fireplace, make sure you have the items listed below.
• external regulator for propane/LP unit only (supplied by installer) | |
• piping (check local codes) | |
• | sealant (resistant to propane/LP gas) |
• | equipment shutoff valve * |
Note:
All Vertical mea- surements are from top of fireplace opening to bottom of mantel shelf.
Minimum Non-
Combustible
Material
10"
8"
6"
2 1/2"
13" | 16" |
Mantel
Shelf
19" |
| 21" |
| ||
|
|
|
• test gauge connection * | |
• | sediment trap (optional) |
• | tee joint |
• | pipe wrench |
• approved flexible gas line with gas connector (if allowed by lo- | |
| cal codes) (not provided) |
*A CSA
For propane/LP units, the installer must supply an external regula- tor. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent point- ing down as shown in Figure 17. Pointing the vent down protects it from freezing rain or sleet.
Figure 16 - Minimum Mantel Clearances for Built-In Installation
INSTALLING GAS PIPING TO FIREPLACE LOCATION
WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pres- sure regulator.
WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.
CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This fireplace requires an external regulator (not supplied). Install the external regulator between the fireplace and pro- pane/LP supply.
WARNING: Never connect natural gas fireplace to private
CAUTION: Use only new, black iron or steel pipe.
External | Propane/LP | |
Supply Tank | ||
Regulator | ||
|
Vent
Pointing
Down
Figure 17 - External Regulator on Propane/LP Supply Tank with Vent Pointing Down