Desa EFS33NR, EFS33NRA, EFS33PR, EFS33PRA VSGF33NR, VSGF33NRA, VSGF33PR, VSGF33PRA Wiring Diagram

Models: EFS33NR, EFS33NRA, EFS33PR, EFS33PRA VSGF33NR, VSGF33NRA, VSGF33PR, VSGF33PRA VSGF33PRA

1 34
Download 34 pages 3.38 Kb
Page 23
Image 23
WIRING DIAGRAM

WIRING DIAGRAM

Note: For proper operation of optional accessories, the wires from the switch to the control must be connected exactly as shown.

A

 

UT

O

OF

ON

F

 

Thermopile

SPECIFICATIONS

MODELS EFS33NR, EFS33NRA, VSGF33NR, and VSGF33NRA

Btu (Variable)

20,000/33,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

Minimum*

5"

Shipping Weight

122 lbs.

* For input adjustment

 

MODELS EFS33PR, EFS33PRA, VSGF33PR, and VSGF33PRA

Btu (Variable)

20,000/33,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

7.9" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

13"

Minimum*

11"

Shipping Weight

122 lbs.

* For input adjustment

 

WIRING DIAGRAM

SPECIFICATIONS 23

REPLACEMENT PARTS

SERVICE HINTS

TECHNICAL SERVICE

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040.

When calling DESA Heating Products, have ready

your name and address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

model number of your fireplace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low for propane/LP unit

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical services web site at www.desatech.com.

For moreSPECIFICATIONSMODELS EFS33NR, EFS33NRA, VSGF33NR, and VSGF33NRAMODELS EFS33PR, EFS33PRA, VSGF33PR, and VSGF33PRAvisit www.REPLACEMENT PARTSPARTS UNDER WARRANTYPARTS NOT UNDER WARRANTY.comSERVICE HINTSWhen Gas Pressure Is Too LowTECHNICAL SERVICEManual background

107172-01G

Page 23
Image 23
Desa EFS33NR, EFS33NRA, EFS33PR, EFS33PRA VSGF33NR, VSGF33NRA, VSGF33PR, VSGF33PRA Wiring Diagram, Specifications