Desa FA-5B, FA-3B Lighting Instructions, To Select Heating Level, To Turn Off Gas To Appliance

Models: FAS-5C FAS-3C FA-3B FA-5B

1 28
Download 28 pages 29.94 Kb
Page 12
Image 12
LIGHTING

INFRARED NATURAL GAS HEATER

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information

 

page 11, column 3.

 

2.

Make sure equipment shutoff valve

 

is fully open.

 

3.

Turn control knob clockwise

 

to the OFF position.

 

4.

Wait five minutes to clear out any

 

gas. Then smell for gas, including

 

near the floor. If you smell gas,

 

STOP! Follow “B” in the safety in-

 

formation page 11, column 3. If you

 

don’t smell gas, go to the next step.

5.

Press in and turn control knob coun-

 

terclockwise

to PILOT/IGN

 

position. Press in control knob for

 

five (5) seconds (see Figure 19).

 

Note: You may be running this heater

 

for the first time after hooking up to

 

gas supply. If so, you may need to press

 

in control knob for 30 seconds. This will

 

allow air to bleed from the gas system.

 

• If control knob does not pop up when

 

released, contact a qualified service

 

person or supplier for repairs.

6.

Release downward pressure on con-

 

trol knob and turn clockwise

 

to OFF position.

 

7.

Press in control knob and turn back

 

to PILOT/IGN. This will cause the

Figure 17 - Control Knob In The OFF Position

 

Ignitor Electrode

Thermocouple

Pilot Burner

 

Figure 18 - Pilot

TO SELECT

HEATING LEVEL

TO SELECT WARNING: When running heater, set control knob at LOW, MEDIUM, or HIGH locked posi- tions. Never set control knob be- tween locked positions. Poor combustion and higher levels of carbon monoxide may result.

TO TURN OFF GAS CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Slightlypressincontrolknobandturncoun-

terclockwise Shutting Off Heater to the LOW, ME- DIUM, or HIGH positions (see Figure 19).

IMPORTANT: Release downward pres- sure while turning control knob. Control knob will lock at the desired position.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise Shutting Off Burner Only (pilot stays lit) to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise MANUAL LIGHTING to the PILOT/IGN position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions.

2.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

piezo ignitor to spark and light the

pilot gas. If needed, repeat steps 5

through 7 until pilot lights.

Note: If pilot does not stay lit, refer

to Troubleshooting, pages 15 through

17. Also contact a qualified service

person or gas supplier for repairs.

Until repairs are made, light pilot

with match. To light pilot with match,

see Manual Lighting Procedure.

8 . Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

Control

 

 

Knob

FA-3B

FA-5B

LOW

MED

HIGH

OFF

Figure 19 - Burner Patterns

12

105566

Page 12
Image 12
Desa FA-5B, FA-3B Lighting Instructions, To Select Heating Level, To Turn Off Gas To Appliance, Manual Lighting Procedure