Venting with Two 90° Elbows
Vertical (V1) Horizontal (H)
5' min. 6' max.
6' min. 12' max.
7' min. 18' max.
8' min. 20' max.
Note:
Vertical (V1) +
Vertical (V2) = 20' max.
Figure 38 - Vertical Venting Configuration Using Two 90
°
Elbows
VENTING INSTALLATION
Continued
Venting with Two 90° Elbows
Vertical (V) Horizontal (H1) +
Horizontal (H2)
5' min. 2' max.
6' min. 4' max.
7' min. 6' max.
8' min. 8' max.
20' max. 8' max.
Figure 37 - Vertical Venting Configuration Using Two 90
°
Elbows
with Two Horizontal Runs
Note:
Install
restrictor into 4"
collar of burner
system as shown.
Note:
Install
restrictor into 4"
collar of burner
system as shown.
PA-47
VENTING INSTALLATION
Installation for Vertical Termination (Cont.)
PA-47