Desa GENERATOR Connect T2 and T3. Measure resistance between T1 and T4, P.O. Box, Stator Main

Models: GENERATOR

1 4
Download 4 pages 18.78 Kb
Page 4
Image 4
Stator Main

Auto-Idle

Control Board

S2 Solenoid S1 T1-3 L1 L2

Red

250V 50A Receptacle

White

Green

250V 30A

Receptacle

White

 

Green

 

 

Black

125V, 30A

125V, 15A

GFCI 125V, 15A

Receptacle

Receptacle

Receptacle

Black

Stator AuxiliaryCircuit Breaker

White

White

To

Auto-Idle

Solenoid

Red

Yellow

Yellow

Capacitor

Circuit

Breaker

45A Winding ∆

* Connect T2 and T3. Measure resistance between T1 and T4. Circuit

Breaker

45A

Red

Yellow

Green

Black

RedMain

White Windings

Circuit Red

Breaker

30A † Remove diodes to check resistance.

Circuit

 

Breaker

Wh

30A

White

Black

White

Black Run Black

Light

Hour Meter

Black

Red

Black

White

White White

Green

Green

Green

BlackBlack

Black

20A

Black

Circuit

Breaker

P.O. Box 90004 20A

White White

T1

T4

T3

T2

T1

T3

T4

Rotor

Stator

Stator

T2

 

 

 

 

 

 

 

T1

T2

T3

T4

Diode

Diode

220/240V

 

 

 

 

L1L2

110/120V 110/120V

 

 

Resistance in Ohms

 

 

 

 

 

 

 

 

 

 

Rated

Stator Main

Stator Auxiliary

Rotor Primary

Rotor Secondary

Capacitor,

Diodes,

Watts

Winding *

Winding

Winding †

Winding †

MFD 450 Volt

(2) 800 Volt

 

 

 

 

 

 

 

10,000

0.4

0.9

0.37

0.5

80

70Amp

 

 

 

 

 

 

 

* Connect T2 and T3. Measure resistance between T1 and T4.

Disconnect capacitor leads in order to read auxillary winding resistance.

† Remove diodes to check resistance.

P.O. Box 90004

 

Bowling Green, KY 42102-9004

103166-01

Technical Service Department 1-800-858-8501

Rev. D

www.desatech.com

07/03

Page 4
Image 4