Desa GS38 installation manual Checking GAS Connections, Checking Gas Connections

Models: GS38

1 36
Download 36 pages 6.77 Kb
Page 14
Image 14

Installation

Continued

3.Route gas supply line through access opening of fireplace insert (see Figure 15).

NOTICE: Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 16). The flexible gas supply line con- nection to the equipment shutoff valve should be accessible.

4.Connect gas supply line to flexible gas line at- tached to gas regulator of fireplace insert (see Figure 16). Use sealant on all male pipe threads.

5.Check all gas connections for leaks. See

Checking Gas Connections.

6.Replace log base assembly back into fireplace insert. Feed flexible gas line into fireplace insert base area while replacing log base as- sembly. Make sure the entire flexible gas line is in fireplace insert base area. Reattach log base assembly to fireplace insert with screws removed in step 2, page 13.

Burners

Two

Screws Log Base

AssemblyGas

Line

Access

Figure 15 - Removing Log Base Assembly From Fireplace Insert

To Fireplace

 

Gas Regulator

Equipment

 

 

Shutoff Valve

 

Propane/LP

 

To External

Flexible Gas Line

Regulator

 

from Fireplace Gas

 

Regulator Provided

Natural

with Fireplace Insert

To Gas Meter

Figure 16 - Attaching Flexible Gas Lines

Together

CHECKING GAS CONNECTIONS

WARNING:Testallgas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detec- tion fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply

Piping System

Test Pressures In Excess Of 1/2 PSIG

(3.5 kPa)

1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace insert gas regulator.

2. Cap off open end of gas pipe where equipment shutoff valve was connected.

3. Pressurize supply piping system by either open- ing propane/LP supply tank for propane/LP gas or opening main gas valve located on or near gas meter or using compressed air.

4. Check all joints of gas supply piping system. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5. Correct all leaks at once.

6. Reconnect fireplace insert and equipment shut- off valve to gas supply. Check reconnected fittings for leaks.

14

www.desatech.com

113195-01C

Page 14
Image 14
Desa GS38 installation manual Checking GAS Connections, Checking Gas Connections

GS38 specifications

Desa GS38 is an innovative product that stands at the intersection of cutting-edge technology and eco-friendly design, making it a standout choice in its category. This model is an embodiment of modern engineering and functionality, catering to the needs of both residential and commercial applications.

One of the defining features of the Desa GS38 is its energy-efficient performance. Designed to minimize energy consumption while maximizing output, the GS38 utilizes advanced technologies that optimize fuel efficiency. This not only helps in reducing utility bills but also aligns with global efforts toward sustainability, making it an environmentally responsible choice. The efficient combustion system integrated into the device ensures that emissions are kept to a minimum, further contributing to a cleaner atmosphere.

Technologically, the Desa GS38 is equipped with a state-of-the-art digital control system. This allows users to monitor and adjust settings with precision, leading to greater comfort and convenience. The intuitive interface makes it easy to program heating schedules, ensuring that spaces are warmed up before they are used, eliminating energy wastage. The device also features smart connectivity, allowing it to be integrated with home automation systems for remote control and operation.

Another significant characteristic of the Desa GS38 is its robust build quality. Made from high-grade materials, the unit is designed to withstand harsh conditions while maintaining operational excellence. The heat-resistant components extend the lifespan of the product, ensuring reliability even during peak usage times.

Safety is also a priority in the design of the Desa GS38. Equipped with multiple safety features such as overheat protection and automated shut-off mechanisms, users can have peace of mind knowing that the device operates safely. This makes it an ideal solution for families and businesses alike.

In summary, the Desa GS38 is a remarkable heating solution that combines energy efficiency, advanced technology, and outstanding durability. Its user-friendly interface, smart connectivity, and safety features make it a versatile choice for various applications. As we move toward a more sustainable future, the Desa GS38 marks a significant step in the direction of eco-conscious innovation in heating solutions.