PRE-INSTALLATION PREPARATION

Mantel Clearances and Wall Details

7

PRE-INSTALLATION

PREPARATION

Continued

MANTEL CLEARANCES AND WALL DETAILS

A combustible mantle shelf maybe installed a maximum 12" (229mm) from the wall. Figures 5 and 6 show the minimum allowable distances from various combustible mantle components in relation to the fire- place opening.

12"

Combustible

(229mm)

Materials

Header

6" (152mm)

TOP VIEW

Outer Surround

Combustible

Material May

Be Used

1 1/2" (38mm)

SAFE

ZONE

Max.

3" (76mm)

 

 

 

 

Max.

 

6" (152mm) Max.

A

Perpendicular

B Wall

A

 

 

M36(B,H)

M42(B,H)

B

Spacer

 

VM36(B,H)

VM42(B,H)

A

9" (229mm)

6" (152mm)

 

 

 

 

B

12" (305mm)

9" (229mm)

3" (76mm)

Figure 6 - Side Clearances - Top View (Cross Section)

1 1/2"

(38mm) Max.

 

M36(B,H)

M42(B,H)

 

VM36(B,H)

VM42(B,H)

A

14" (356mm)

15" (381mm)

B

8" (203mm)

9" (229mm)

 

 

 

Figure 5 - Mantel Clearances - Side View (Cross Section)

For more information, visit www.desatech.com

108795

Page 7
Image 7
Desa installation manual Mantel Clearances and Wall Details, M36B,H M42B,H VM36B,H VM42B,H