OPERATION

Continued

20

PRESTART

Operate generator on a firm, dry, and clean surface. The surface must be level. Protect generator from heavy dust, sand, dirt, rain, or snow. Do not locate genera- tor near standing water and snow. Make sure area is well-vented.

WARNING

Only responsible adults should use generator. Never let anyone operate generator without proper instruc- tions.

Note: If oil level is too low, oil alert system will keep engine from starting (see Oil Alert System, page 9). Make sure oil level is full before starting. See Engine Oil, page 11.

Before starting the engine, disconnect all electric loads from generator.

STARTING

IMPORTANT: The engine speed is preset. The throttle is locked in preset posi- tion. Do not adjust throttle. Preset position lets engine run at 3600 RPM under load. The engine must maintain 3600 RPM for generator to create correct voltage. Running engine at lower speeds will damage generator and powered items.

IMPORTANT: Never start generator with electrical loads connected. Start engine before adding electrical loads.

1.Make sure gasoline tank is full. See Fuel, page 12 for fuel information.

2.Move fuel valve lever to the ON position (see Figure 15).

3.Move choke lever fully to the left (see Figure 15). This closes the choke.

Note: You may not need to close choke if engine is warm or air temperature is high.

Choke Lever (Closed Position)

Fuel Valve Lever (ON Position)

Figure 15 - Fuel Valve Lever On, Choke Lever Closed

Page 20
Image 20
Desa Mgh3000, Mgh4000a, Mgh5000a, Mgh6000, Mgh7000 installation manual Prestart, Starting