1.Turn control knob clockwise to the PILOT position.

2.Press in and turn control clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

TROUBLESHOOTING

Note: For additional help, visit DESA International’s Technical Service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off log set and let cool before servicing. Only a qualified service person should service and repair log set.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Log set is smoking/sooting excessively

1.

Poor fuel quality

1.

Contact local natural or propane/LP gas

(Note: It is natural and unavoidable for

 

 

 

company

vented gas log sets to produce moderate

2.

Fireplace venting system not drafting

2.

Adjust damper wide open and/or have

levels of carbon (soot) where flames

 

properly

 

fireplace and venting professionally

contact the logs. This is especially true

 

 

 

cleaned and checked

with propane/LP gas.)

3.

Excessive flame impingement or block-

3.

Separate the logs to allow more flame

 

 

age

 

passage

 

4.

Improper fuel/air mixture

4.

Remove any foreign items from the

 

 

 

 

flame pattern and/or check for proper

 

 

 

 

orifice sizing

 

5.

Excessive gas supply/pressure

5.

Preheat flue in very cold weather

Burner is excessively noisy

(Note: The movement and combustion of gas will create low, unavoidable levels of noise.)

1.Passage of air/gas across irregular sur- faces

1.Relieve any tight bends or kinks in gas supply line

Burner flame is too low or too high

1.

Incorrect gas supply or pressure

1.

Check for proper gas supply pressure

 

2.

Blocked burner orifice or burner mani-

2.

Free burner orifice and manifold ports

 

 

fold ports

 

of any burrs, paint, or other blockage

 

3.

Improper burner orifice size

3.

Verify proper burner orifice sizing (see

 

 

 

 

Figure 4, page 7)

www.desatech.com

Continued

901747

13

Page 13
Image 13
Desa PCVDR24 RGA Troubleshooting, To Turn OFF GAS To Appliance, Shutting Off Burner Only pilot stays lit

PCVDR24 RGA specifications

Desa PCVDR24 RGA is a cutting-edge device designed to enhance temperature management in residential and commercial spaces. This innovative product stands out in the market thanks to its advanced technology and user-friendly features.

At its core, the PCVDR24 RGA offers precise temperature control, allowing users to maintain their desired comfort levels efficiently. It uses a highly responsive digital thermostat, which ensures accurate readings and minimal temperature fluctuations. This feature not only contributes to user comfort but also promotes energy efficiency, as the system avoids unnecessary heating or cooling cycles.

One of the key features of the Desa PCVDR24 RGA is its robust construction. Designed for durability, this unit is built to withstand varying environmental conditions, making it suitable for both indoor and outdoor applications. The materials used in its construction resist rust and corrosion, ensuring a long lifespan even in harsh climates.

The PCVDR24 RGA also employs advanced airflow technology, which facilitates even distribution of heated or cooled air. This ensures that every corner of the room reaches the desired temperature without hot or cold spots, significantly enhancing comfort levels for occupants.

Furthermore, the device is equipped with programmable settings, allowing users to tailor temperature schedules based on their daily routines. This smart feature not only enhances user convenience but also contributes to energy savings, as homeowners and business operators can adjust the heating and cooling cycles to operate according to their specific needs.

Additionally, the Desa PCVDR24 RGA comes with a built-in safety mechanism designed to prevent overheating. This greatly reduces the risk of potential accidents, ensuring a safe environment for all users.

In terms of energy efficiency, the PCVDR24 RGA is designed to meet rigorous industry standards, making it an environmentally friendly choice. Users can expect a reduction in energy bills due to its efficient operation, which is increasingly important in today’s eco-conscious society.

In summary, the Desa PCVDR24 RGA combines advanced technology, robust construction, and user-friendly features to provide a reliable solution for temperature management. Its precise control, even airflow distribution, programmable settings, and safety features make it an attractive option for anyone looking to improve comfort and energy efficiency in their space.