Desa PGH7500IE, PGH1100IE installation manual Operation, General Information, Using Receptacle

Models: PGH7500IE, PGH1100IE

1 26
Download 26 pages 46.02 Kb
Page 11
Image 11
OPERATION

OWNER’S MANUAL

OPERATION

GENERAL INFORMATION

This generator is not large enough to power your entire home. Do not connect generator to any existing electrical circuits. Plug items directly into generator receptacles. Do not exceed amperage rating of receptacles. Only use grounded cords.

GENERAL INFORMATION DANGER: Use only in well- vented areas. Make sure area has plenty of free-moving, fresh, out- side air. Never run generator in an enclosed or confined area. Never run generator inside occu- pied building. Engine exhaust contains poisonous carbon mon- oxide gas. Overexposure will cause loss of consciousness and will lead to death.

USING RECEPTACLEDANGER: Never connect gen- erator to any existing electrical circuits. The generator output will back-feed into the utility power line. This may electrocute a power company line repair person. Also, if generator is powering electri- cal circuits, the chance of an elec- trical fire exists.

Note: We supply the engine Owner’s Manual with generator. Refer to that manual for questions concerning engine operation.

USING RECEPTACLE

Note: Do not exceed amperage rating of receptacles. Exceeding rating will trip re- ceptacle circuit breaker.

Use receptacles properly. Improper use could damage generator. Use only grounded ex- tension cords. Power only grounded or double-insulated items. Do not overload receptacles. Both generators have the fol- lowing receptacles (see Figure 14):

120V, 15-amp GFCI duplex receptacle

120V, 30-amp twist-lock receptacle

120/240V, 20 or 30-amp twist-lock receptacle

120V, 15-amp duplex receptacle

Model PGH11000IE also has a 120/240V, 50-amp receptacle (see Figure 14).

120V, 15-Amp GFCI Duplex

 

 

 

120V, 15-Amp Duplex

 

 

120/240V, 20 or 30-

120

VOLTS

Amp Twist-Lock

 

 

RESET

 

 

 

TEST

 

 

 

 

120/240

VOLTS

 

 

ENM

 

 

00000005

 

 

 

HOURS

RESET

 

 

1/10

120V, 30-Amp

 

RESET

 

 

Twist-Lock

RESET

240

VOLTS

 

 

RESET

 

RESET

 

 

 

 

RESET

120/240V, 50-Amp

(Model PGH11000IE only)

Figure 14 - Receptacle Locations

POWER CORD AND PLUG REQUIREMENTS

120V, 30-amp twist-lock receptacle

NEMA L5-30P plug

Three-wire, 30-amp cord

120/240V, 20 or 30-amp twist-lock receptacle

NEMA L14-20P (20-amp) or L14-30P (30-amp) plug

Four-wire, 20-amp or 30-amp cord

120/240V, 50-amp receptacle

NEMA L14-50P

Four-wire, 50-amp cord

120/240 Volt

 

 

 

 

20 Amp

 

Neutral

 

 

 

 

 

 

120V

120V

 

Ground

X

 

w

L14-20P

Y

X

(Green)

(Hot)

 

G

Plug

 

 

Ground

 

Y

W

 

 

 

(Neutral)

 

 

 

(Hot)

 

 

 

 

 

 

 

Figure 15 - Cord and Plug Configurations

Continued

106746

11

Page 11
Image 11
Desa PGH7500IE, PGH1100IE Operation, General Information, Using Receptacle, Power Cord And Plug Requirements