Desa PHK-18, PHK-24, PHK-30 Installation, Flue Opening Specifications, Check Gas Type

Models: BCS18, BCS24, BCS30 PHK-18, PHK-24, PHK-30

1 16
Download 16 pages 36.34 Kb
Page 4
Image 4
INSTALLATION

4

INSTALLATION

Flue Opening Specifications Check Gas Type

Venting Specifications for Installation

INSTALLATION

FLUE OPENING SPECIFICATIONSCAUTION: Do not remove the data plates attached to the burner pan. The data plates contain important warranty information.

CHECK GAS TYPE WARNING: Before installing in a solid fuel burning fireplace,thechimneyflueandfireboxmustbecleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue before operating heater.

NOTICE: Installation, service, and repair of this appli- ancemustbeperformedbyaqualifiedinstaller,service agency, company or gas supplier experienced with this type of gas appliance. Only factory authorized components listed in these instructions may be used in accordance with the manufacturer’s instructions

Model

Burner

 

 

BTU Input

 

 

Minimum Vent

Description

 

(Natural Gas)

 

Opening

 

 

 

PHK/ BCS 18

18" Ramp

 

57,000

 

 

 

8"

PHK/ BCS 24

24" Ramp

 

80,000

 

 

 

8"

PHK/ BCS 30

30" Ramp

 

90,000

 

 

 

8"

 

 

 

 

 

 

 

 

Minimum Fireplace Dimensions

 

 

Model

 

Front

 

Back

 

Depth

Height

 

Width

 

Width*

 

 

 

 

 

 

 

 

 

PHK/ BCS 18

 

28"

 

 

18"

 

16"

 

18"

PHK/ BCS 24

 

36"

 

 

23"

 

16"

 

18"

PHK/ BCS 30

 

42"

 

 

29"

 

18"

 

18"

* At depth Indicated

and all codes and requirements of the authority hav- ing jurisdiction. Any modifications to this kit, or use of unauthorized components or accessory items will void the manufacturer’s warranty, and may result in a hazardous condition.

FLUE OPENING SPECIFICATIONS

Fuel Inlet Pressure Specifi cations (W.C.)

Min. Max.

N.G. 5.5" 10.5"

Burner Orifi ce Sizing

Log Size

Natural Gas

In.

Num.

 

18"

.120

31

24"

.140

28

30"

.1495

25

Note: This vented appliance must be installed only in a solid-fuel burning fi replace with a working fl ue and constructed of noncom- bustible material.

The charts in Figure 2 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifi cations shown are applicable before installation is at- tempted.

The fi replace must include a working fl ue and venting system with

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, you MUST NOT install this gas log set

If the fireplace does not have a gas supply shutoff valve, one must be installed.

Figure 2 - Technical Information Charts

VENTING SPECIFICATIONS FOR

INSTALLATION

The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace. Ob- serve the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.

The chimney flue must remain open a minimum of 3" at all times during the operation of this log set.

For more information, visit www.desatech.com

115425-01

Page 4
Image 4
Desa PHK-18, PHK-24, PHK-30, BCS18, BCS24, BCS30 Installation, Flue Opening Specifications, Check Gas Type