Desa PROPANE CONSTRUCTION CONVECTION HEATER Storage, Continued, Operation, Flame Patterns

Models: PROPANE CONSTRUCTION CONVECTION HEATER

1 24
Download 24 pages 8.67 Kb
Page 5
Image 5
Continued

OPERATION STORAGE

5

OPERATION

Continued

7.After ignition, hold control knob down for about 30 seconds. This activates the automatic control system.

8.When burner remains lit, set heater at the desired heat level by slightly depressing the control knob and turning it counterclock- wise to the MED or HIGH settings (see Figure 4, page 4).

9.If burner goes out, turn off gas. Slightly depress and turn con- trol knob fully clockwise to OFF. Check fuel supply. If ad- equate fuel is available, restart heater beginning at step #1, page 4.

FLAME PATTERNS

Figure 5 shows a correct flame pattern. The burner flame is mostly blue with a slight yellow coloring on the ends.

Figure 6 shows an incorrect flame pattern. The flame is mostly yellow. The incorrect flame pattern results from low gas pressure or from flashback.

FLAME PATTERNS CAUTION: Running heater below specified input rating may cause flashback. During flashback, the burner flame is mostly yellow. The flame will burn inside the burner tube, causing a roaring noise. If flashback occurs, turn heater off. After burner tube cools, restart the heater.

Yellow Flame

Flame Inside

Blue

Flame

Burner Tube

 

(makes roaring

 

noise)

 

Figure 6 - Incorrect Flame Pattern During Flashback

Slight Yellow Coloring on Flame Ends

Burner

Tube

Blue

Flame

TO STOP HEATER

1.Tightly close propane supply valve on propane tank(s). Allow heater to burn remaining fuel in hose.

2.Shut off burner. Do this by pushing in the control knob and turning clockwise to the OFF position.

TO RESTART HEATER

1.Wait five minutes after stopping heater.

2.Restart heater by following steps under To Start Heater, page 4.

STORAGE

TO STOP HEATER CAUTION: Disconnect heater from propane sup- ply tank(s).

1.Store propane tank(s) in safe manner. Refer to Chapter 5 of Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and/or CAN/CGA B149.2. Follow all local codes. Always store propane tanks outdoors.

2.Place plastic cover caps over brass fittings on inlet connector and hose/regulator assembly.

3.Store in a dry, clean, and safe place.

Figure 5 - Correct Flame Pattern at High Position

TO RESTART HEATERSTORAGEManual backgroundManual backgroundFor more information, visit www.desatech.com

111695-01B

Page 5
Image 5